Sparsity and locally low rank regularization for MR fingerprinting. Issue 6 (5th February 2019)
- Record Type:
- Journal Article
- Title:
- Sparsity and locally low rank regularization for MR fingerprinting. Issue 6 (5th February 2019)
- Main Title:
- Sparsity and locally low rank regularization for MR fingerprinting
- Authors:
- Lima da Cruz, Gastão
Bustin, Aurélien
Jaubert, Oliver
Schneider, Torben
Botnar, René M.
Prieto, Claudia - Abstract:
- Abstract : Purpose: Develop a sparse and locally low rank (LLR) regularized reconstruction to accelerate MR fingerprinting (MRF). Methods: Recent works have introduced low rank reconstructions to MRF, based on temporal compression operators learned from the MRF dictionary. In other MR applications, LLR regularization has been introduced to exploit temporal redundancy in local regions of the image. Here, we propose to include spatial sparsity and LLR regularization terms in the MRF reconstruction. This approach, so called SLLR‐MRF, further reduces aliasing in the time‐point images and enables higher acceleration factors. The proposed approach was evaluated in simulations, T1 /T2 phantom acquisition, and in vivo brain acquisitions in 5 healthy subjects with different undersampling factors. Acceleration was also used in vivo to enable acquisitions with higher in‐plane spatial resolution in comparable scan time. Results: Simulations, phantom, and in vivo results show that low rank MRF reconstructions with high acceleration factors (<875 time‐point images, 1 radial spoke per time‐point) have residual aliasing artifacts that propagate into the parametric maps. The artifacts are reduced with the proposed SLLR‐MRF resulting in considerable improvements in precision, without changes in accuracy. In vivo results show improved parametric maps for the proposed SLLR‐MRF, potentially enabling MRF acquisitions with 1 radial spoke per time‐point in approximately 2.6 s (~600 time‐pointAbstract : Purpose: Develop a sparse and locally low rank (LLR) regularized reconstruction to accelerate MR fingerprinting (MRF). Methods: Recent works have introduced low rank reconstructions to MRF, based on temporal compression operators learned from the MRF dictionary. In other MR applications, LLR regularization has been introduced to exploit temporal redundancy in local regions of the image. Here, we propose to include spatial sparsity and LLR regularization terms in the MRF reconstruction. This approach, so called SLLR‐MRF, further reduces aliasing in the time‐point images and enables higher acceleration factors. The proposed approach was evaluated in simulations, T1 /T2 phantom acquisition, and in vivo brain acquisitions in 5 healthy subjects with different undersampling factors. Acceleration was also used in vivo to enable acquisitions with higher in‐plane spatial resolution in comparable scan time. Results: Simulations, phantom, and in vivo results show that low rank MRF reconstructions with high acceleration factors (<875 time‐point images, 1 radial spoke per time‐point) have residual aliasing artifacts that propagate into the parametric maps. The artifacts are reduced with the proposed SLLR‐MRF resulting in considerable improvements in precision, without changes in accuracy. In vivo results show improved parametric maps for the proposed SLLR‐MRF, potentially enabling MRF acquisitions with 1 radial spoke per time‐point in approximately 2.6 s (~600 time‐point images) for 2 × 2 mm and 9.6 s (1750 time‐point images) for 1 × 1 mm in‐plane resolution. Conclusion: The proposed SLLR‐MRF reconstruction further improves parametric map quality compared with low rank MRF, enabling shorter scan times and/or increased spatial resolution. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 6(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 6(2019)
- Issue Display:
- Volume 81, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 6
- Issue Sort Value:
- 2019-0081-0006-0000
- Page Start:
- 3530
- Page End:
- 3543
- Publication Date:
- 2019-02-05
- Subjects:
- compressed sensing -- locally low rank -- low rank -- MR fingerprinting -- quantitative MRI
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27665 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12875.xml