A method for correcting breathing‐induced field fluctuations in T2*‐weighted spinal cord imaging using a respiratory trace. Issue 6 (8th February 2019)
- Record Type:
- Journal Article
- Title:
- A method for correcting breathing‐induced field fluctuations in T2*‐weighted spinal cord imaging using a respiratory trace. Issue 6 (8th February 2019)
- Main Title:
- A method for correcting breathing‐induced field fluctuations in T2*‐weighted spinal cord imaging using a respiratory trace
- Authors:
- Vannesjo, S. Johanna
Clare, Stuart
Kasper, Lars
Tracey, Irene
Miller, Karla L. - Abstract:
- Abstract : Purpose: Spinal cord MRI at ultrahigh field is hampered by time‐varying magnetic fields associated with the breathing cycle, giving rise to ghosting artifacts in multi‐shot acquisitions. Here, we suggest a correction approach based on linking the signal from a respiratory bellows to field changes inside the spinal cord. The information is used to correct the data at the image reconstruction level. Methods: The correction was demonstrated in the context of multi‐shot T2*‐weighted imaging of the cervical spinal cord at 7T. A respiratory trace was acquired during a high‐resolution multi‐echo gradient‐echo sequence, used for structural imaging and quantitative T2* mapping, and a multi‐shot EPI time series, as would be suitable for fMRI. The coupling between the trace and the breathing‐induced fields was determined by a short calibration scan in each individual. Images were reconstructed with and without trace‐based correction. Results: In the multi‐echo acquisition, breathing‐induced fields caused severe ghosting in images with long TE, which led to a systematic underestimation of T2* in the spinal cord. The trace‐based correction reduced the ghosting and increased the estimated T2* values. Breathing‐related ghosting was also observed in the multi‐shot EPI images. The correction largely removed the ghosting, thereby improving the temporal signal‐to‐noise ratio of the time series. Conclusions: Trace‐based retrospective correction of breathing‐induced field variationsAbstract : Purpose: Spinal cord MRI at ultrahigh field is hampered by time‐varying magnetic fields associated with the breathing cycle, giving rise to ghosting artifacts in multi‐shot acquisitions. Here, we suggest a correction approach based on linking the signal from a respiratory bellows to field changes inside the spinal cord. The information is used to correct the data at the image reconstruction level. Methods: The correction was demonstrated in the context of multi‐shot T2*‐weighted imaging of the cervical spinal cord at 7T. A respiratory trace was acquired during a high‐resolution multi‐echo gradient‐echo sequence, used for structural imaging and quantitative T2* mapping, and a multi‐shot EPI time series, as would be suitable for fMRI. The coupling between the trace and the breathing‐induced fields was determined by a short calibration scan in each individual. Images were reconstructed with and without trace‐based correction. Results: In the multi‐echo acquisition, breathing‐induced fields caused severe ghosting in images with long TE, which led to a systematic underestimation of T2* in the spinal cord. The trace‐based correction reduced the ghosting and increased the estimated T2* values. Breathing‐related ghosting was also observed in the multi‐shot EPI images. The correction largely removed the ghosting, thereby improving the temporal signal‐to‐noise ratio of the time series. Conclusions: Trace‐based retrospective correction of breathing‐induced field variations can reduce ghosting and improve quantitative metrics in multi‐shot structural and functional T2*‐weighted imaging of the spinal cord. The method is straightforward to implement and does not rely on sequence modifications or additional hardware beyond a respiratory bellows. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 81:Issue 6(2019)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 81:Issue 6(2019)
- Issue Display:
- Volume 81, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 81
- Issue:
- 6
- Issue Sort Value:
- 2019-0081-0006-0000
- Page Start:
- 3745
- Page End:
- 3753
- Publication Date:
- 2019-02-08
- Subjects:
- 7T MRI -- breathing‐induced field fluctuations -- multi‐shot EPI -- spinal cord imaging -- T2* mapping
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.27664 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12875.xml