An in vitro and in vivo characterization of fine WE43B magnesium wire with varied thermomechanical processing conditions. Issue 5 (9th October 2017)
- Record Type:
- Journal Article
- Title:
- An in vitro and in vivo characterization of fine WE43B magnesium wire with varied thermomechanical processing conditions. Issue 5 (9th October 2017)
- Main Title:
- An in vitro and in vivo characterization of fine WE43B magnesium wire with varied thermomechanical processing conditions
- Authors:
- Griebel, Adam J.
Schaffer, Jeremy E.
Hopkins, Tracy M.
Alghalayini, Alaa
Mkorombindo, Tinomudaishe
Ojo, Kolade O.
Xu, Zhigang
Little, Kevin J.
Pixley, Sarah K. - Abstract:
- Abstract: Absorbable implants made of magnesium alloys may revolutionize surgical intervention, and fine magnesium wire will be critical to many applications. Functionally, the wires must have sufficient mechanical properties to withstand implantation and in‐service loading, have excellent tissue tolerance, and exhibit an appropriate degradation rate for the application. Alloy chemistry and thermomechanical processing conditions will significantly impact the material's functional performance, but the exact translation of these parameters to implant performance is unclear. With this in mind, fine (127 µm) WE43B magnesium alloy wires in five thermomechanical process (TMP) conditions (90% cold work [CW], and 250, 375, 400, and 450°C heat treatments) were investigated for their effect on mechanical and corrosion behavior. The TMP conditions gave clear metallurgical differences: transverse grain dimensions ranged from 200 nm (CW) to 3 µm (450°C), UTS varied from 324 MPa (450°C) to 608 MPa (250°C), and surgical knotting showed some were suitable (CW, 400°C, 450°C) while others were not (250°C, 350°C). In vitro and in vivo corrosion testing yielded interesting and in some cases conflicting results. After 1 month immersion in cell culture medium, wire corrosion was extensive, and TMP conditions altered the macrocorrosion morphology but not the rate or total release of magnesium ions. After 1 month subdermal implantation in mice, all wires were well tolerated and showed very littleAbstract: Absorbable implants made of magnesium alloys may revolutionize surgical intervention, and fine magnesium wire will be critical to many applications. Functionally, the wires must have sufficient mechanical properties to withstand implantation and in‐service loading, have excellent tissue tolerance, and exhibit an appropriate degradation rate for the application. Alloy chemistry and thermomechanical processing conditions will significantly impact the material's functional performance, but the exact translation of these parameters to implant performance is unclear. With this in mind, fine (127 µm) WE43B magnesium alloy wires in five thermomechanical process (TMP) conditions (90% cold work [CW], and 250, 375, 400, and 450°C heat treatments) were investigated for their effect on mechanical and corrosion behavior. The TMP conditions gave clear metallurgical differences: transverse grain dimensions ranged from 200 nm (CW) to 3 µm (450°C), UTS varied from 324 MPa (450°C) to 608 MPa (250°C), and surgical knotting showed some were suitable (CW, 400°C, 450°C) while others were not (250°C, 350°C). In vitro and in vivo corrosion testing yielded interesting and in some cases conflicting results. After 1 month immersion in cell culture medium, wire corrosion was extensive, and TMP conditions altered the macrocorrosion morphology but not the rate or total release of magnesium ions. After 1 month subdermal implantation in mice, all wires were well tolerated and showed very little corrosion (per µCT and histology), but differences in localized corrosion were detected between conditions. This study indicates that WE43B wires treated at 450°C may be most suitable for surgical knotting procedures. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1987–1997, 2018. … (more)
- Is Part Of:
- Journal of biomedical materials research. Volume 106:Issue 5(2018)
- Journal:
- Journal of biomedical materials research
- Issue:
- Volume 106:Issue 5(2018)
- Issue Display:
- Volume 106, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 106
- Issue:
- 5
- Issue Sort Value:
- 2018-0106-0005-0000
- Page Start:
- 1987
- Page End:
- 1997
- Publication Date:
- 2017-10-09
- Subjects:
- magnesium -- biodegradable metal -- thermomechanical processing -- wire -- WE43B alloy
Biomedical materials -- Periodicals
610.28 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jbm.b.34008 ↗
- Languages:
- English
- ISSNs:
- 1552-4973
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.725000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12876.xml