Roland-Morris Disability Questionnaire and Oswestry Disability Index: Which Has Better Measurement Properties for Measuring Physical Functioning in Nonspecific Low Back Pain? Systematic Review and Meta-Analysis. Issue 10 (1st October 2016)
- Record Type:
- Journal Article
- Title:
- Roland-Morris Disability Questionnaire and Oswestry Disability Index: Which Has Better Measurement Properties for Measuring Physical Functioning in Nonspecific Low Back Pain? Systematic Review and Meta-Analysis. Issue 10 (1st October 2016)
- Main Title:
- Roland-Morris Disability Questionnaire and Oswestry Disability Index: Which Has Better Measurement Properties for Measuring Physical Functioning in Nonspecific Low Back Pain? Systematic Review and Meta-Analysis
- Authors:
- Chiarotto, Alessandro
Maxwell, Lara J.
Terwee, Caroline B.
Wells, George A.
Tugwell, Peter
Ostelo, Raymond W. - Abstract:
- Abstract: Background: Physical functioning is a core outcome domain to be measured in nonspecific low back pain (NSLBP). A panel of experts recommended the Roland-Morris Disability Questionnaire (RMDQ) and Oswestry Disability Index (ODI) to measure this domain. The original 24-item RMDQ and ODI 2.1a are recommended by their developers. Purpose: The purpose of this study was to evaluate whether the 24-item RMDQ or the ODI 2.1a has better measurement properties than the other to measure physical functioning in adult patients with NSLBP. Data Sources: Bibliographic databases (MEDLINE, Embase, CINAHL, SportDiscus, PsycINFO, and Google Scholar), references of existing reviews, and citation tracking were the data sources. Study Selection: Two reviewers selected studies performing a head-to-head comparison of measurement properties (reliability, validity, and responsiveness) of the 2 questionnaires. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist was used to assess the methodological quality of these studies. Data Extraction: The studies' characteristics and results were extracted by 2 reviewers. A meta-analysis was conducted when there was sufficient clinical and methodological homogeneity among studies. Data Synthesis: Nine articles were included, for a total of 11 studies assessing 5 measurement properties. All studies were classified as having poor or fair methodological quality. The ODI displayed better test-retestAbstract: Background: Physical functioning is a core outcome domain to be measured in nonspecific low back pain (NSLBP). A panel of experts recommended the Roland-Morris Disability Questionnaire (RMDQ) and Oswestry Disability Index (ODI) to measure this domain. The original 24-item RMDQ and ODI 2.1a are recommended by their developers. Purpose: The purpose of this study was to evaluate whether the 24-item RMDQ or the ODI 2.1a has better measurement properties than the other to measure physical functioning in adult patients with NSLBP. Data Sources: Bibliographic databases (MEDLINE, Embase, CINAHL, SportDiscus, PsycINFO, and Google Scholar), references of existing reviews, and citation tracking were the data sources. Study Selection: Two reviewers selected studies performing a head-to-head comparison of measurement properties (reliability, validity, and responsiveness) of the 2 questionnaires. The COnsensus-based Standards for the selection of health Measurement INstruments (COSMIN) checklist was used to assess the methodological quality of these studies. Data Extraction: The studies' characteristics and results were extracted by 2 reviewers. A meta-analysis was conducted when there was sufficient clinical and methodological homogeneity among studies. Data Synthesis: Nine articles were included, for a total of 11 studies assessing 5 measurement properties. All studies were classified as having poor or fair methodological quality. The ODI displayed better test-retest reliability and smaller measurement error, whereas the RMDQ presented better construct validity as a measure of physical functioning. There was conflicting evidence for both instruments regarding responsiveness and inconclusive evidence for internal consistency. Limitations: The results of this review are not generalizable to all available versions of these questionnaires or to patients with specific causes for their LBP. Conclusions: Based on existing head-to-head comparison studies, there are no strong reasons to prefer 1 of these 2 instruments to measure physical functioning in patients with NSLBP, but studies of higher quality are needed to confirm this conclusion. Foremost, content, structural, and cross-cultural validity of these questionnaires in patients with NSLBP should be assessed and compared. … (more)
- Is Part Of:
- Physical therapy. Volume 96:Issue 10(2016)
- Journal:
- Physical therapy
- Issue:
- Volume 96:Issue 10(2016)
- Issue Display:
- Volume 96, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 96
- Issue:
- 10
- Issue Sort Value:
- 2016-0096-0010-0000
- Page Start:
- 1620
- Page End:
- 1637
- Publication Date:
- 2016-10-01
- Subjects:
- Physical therapy -- Periodicals
Physical therapy
Physical Therapy Modalities
Rehabilitation
Physical and Rehabilitation Medicine
Periodicals
615.8205 - Journal URLs:
- http://www.searchbank.com/searchbank/lcmlmain ↗
http://www.ptjournal.org ↗
https://academic.oup.com/ptj ↗
http://www.oxfordjournals.org/ ↗ - DOI:
- 10.2522/ptj.20150420 ↗
- Languages:
- English
- ISSNs:
- 0031-9023
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6476.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12860.xml