Clinical Accuracy of the Nidek ARK-1 Autorefractor. Issue 6 (June 2019)
- Record Type:
- Journal Article
- Title:
- Clinical Accuracy of the Nidek ARK-1 Autorefractor. Issue 6 (June 2019)
- Main Title:
- Clinical Accuracy of the Nidek ARK-1 Autorefractor
- Authors:
- Paudel, Nabin
Adhikari, Sameep
Thakur, Ajit
Shrestha, Bhairaja
Loughman, James - Abstract:
- Abstract : SIGNIFICANCE: Autorefractors are commonly used by eye care practitioners worldwide as a starting point for clinical prescribing and by researchers as an instrument to study development of refractive errors and accommodation. This study demonstrates that the Nidek ARK-1 provides a reasonable and repeatable estimate of refractive error. PURPOSE: The purposes of this study were ( a ) to compare refraction measurements of the Nidek ARK-1 (2016 release) autorefractor with that of subjective refraction and retinoscopy performed by an experienced clinician and ( b ) to determine the intratest and intertest variability of autorefraction measures taken using the ARK-1 autorefractor. METHODS: Sixty-seven adult patients aged 18 to 69 years underwent retinoscopy, subjective refraction, and ARK-1 autorefraction on a same day by a single clinician. A separate subset of 14 participants was invited for the repeatability and reproducibility study. Both eyes of each participant were included in the analysis. RESULTS: A statistically significant (but not clinically significant) positive spherical difference was observed between the ARK-1 and subjective refraction ( P = .003). Spherical equivalent refractive errors were statistically similar between the ARK-1 and subjective refraction ( P = .20). A statistically and clinically significant difference was observed in the cylindrical component between the ARK and subjective refraction ( P < .01). No statistically significant differenceAbstract : SIGNIFICANCE: Autorefractors are commonly used by eye care practitioners worldwide as a starting point for clinical prescribing and by researchers as an instrument to study development of refractive errors and accommodation. This study demonstrates that the Nidek ARK-1 provides a reasonable and repeatable estimate of refractive error. PURPOSE: The purposes of this study were ( a ) to compare refraction measurements of the Nidek ARK-1 (2016 release) autorefractor with that of subjective refraction and retinoscopy performed by an experienced clinician and ( b ) to determine the intratest and intertest variability of autorefraction measures taken using the ARK-1 autorefractor. METHODS: Sixty-seven adult patients aged 18 to 69 years underwent retinoscopy, subjective refraction, and ARK-1 autorefraction on a same day by a single clinician. A separate subset of 14 participants was invited for the repeatability and reproducibility study. Both eyes of each participant were included in the analysis. RESULTS: A statistically significant (but not clinically significant) positive spherical difference was observed between the ARK-1 and subjective refraction ( P = .003). Spherical equivalent refractive errors were statistically similar between the ARK-1 and subjective refraction ( P = .20). A statistically and clinically significant difference was observed in the cylindrical component between the ARK and subjective refraction ( P < .01). No statistically significant difference was observed between the ARK and subjective refraction in both the horizontal ( J 0 ; P = .08) and oblique cylindrical vector ( J 45 ; P = .96). Bland-Altman analysis revealed that the 95% limits of agreement were widest between the ARK and subjective refraction in all of the refractive components (−0.60 to 0.89 diopter for spherical component, −0.80 to 0.69 diopter for spherical equivalent, and −0.98 to 0.30 diopter for cylindrical component). The intertest and intratest variability of the ARK-1 was small. CONCLUSIONS: The Nidek ARK-1 autorefractor is a useful clinical tool that provides a reasonable and repeatable estimation of refractive error in adults. … (more)
- Is Part Of:
- Optometry and vision science. Volume 96:Issue 6(2019)
- Journal:
- Optometry and vision science
- Issue:
- Volume 96:Issue 6(2019)
- Issue Display:
- Volume 96, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 96
- Issue:
- 6
- Issue Sort Value:
- 2019-0096-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-06
- Subjects:
- Optometry -- Periodicals
Physiological optics -- Periodicals
Vision disorders -- Periodicals
617.7505 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00006324-000000000-00000 ↗
http://www.optvissci.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/OPX.0000000000001386 ↗
- Languages:
- English
- ISSNs:
- 1040-5488
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6276.450000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12859.xml