Comparative effectiveness of different contemporary drug-eluting stents in routine clinical practice: a multigroup propensity score analysis using data from the stent-specific, multicenter, prospective registries. Issue 4 (June 2019)
- Record Type:
- Journal Article
- Title:
- Comparative effectiveness of different contemporary drug-eluting stents in routine clinical practice: a multigroup propensity score analysis using data from the stent-specific, multicenter, prospective registries. Issue 4 (June 2019)
- Main Title:
- Comparative effectiveness of different contemporary drug-eluting stents in routine clinical practice
- Authors:
- Kwon, Osung
Kang, Se Hun
Lee, Jung-Bok
Ahn, Jung-Min
Lee, Cheol Hyun
Kang, Do-Yoon
Lee, Pil Hyung
Kang, Soo-Jin
Lee, Seung-Whan
Kim, Young-Hak
Lee, Cheol Whan
Park, Seong-Wook
Park, Duk-Woo
Park, Seung-Jung - Abstract:
- Abstract : Objective: Data on the comparative effectiveness of contemporary drug-eluting stents (DES) in the unrestricted, real-world setting are limited. We investigated the long-term effectiveness and safety of contemporary different drug-eluting stents by means of multiple treatment propensity score weighting. Patients and methods: From seven stent-specific, prospective DES registries conducted between July 2007 and July 2015, we evaluated 17 196 patients who received several contemporary DES and first-generation DES: 3053 treated with cobalt–chromium everolimus-eluting stents (CoCr-EES), 2985 with platinum–chromium EES (PtCr-EES), 2922 with Resolute zotarolimus-eluting stents (Re-ZES), 789 with Biomatrix biolimus-eluting stents (Bi-BES), 1907 with Nobori biolimus-eluting stents (No-BES), 1970 with Xience Prime cobalt–chromium everolimus-eluting stents (Pr-CoCr-EES), and 3570 with sirolimus-eluting stents (SES). The primary outcome was target-vessel failure (a composite of cardiac death, target-vessel myocardial infarction, or target-vessel revascularization) at 3 years of follow-up and major cardiovascular adverse events (a composite of all-cause death, any myocardial infarction, or any revascularization) was also evaluated. Results: The observed 3-year rates of target-vessel failure were not significantly different among different second-generation DES and SES (CoCr-EES 9.8%, PtCr-EES 9.5%, Re-ZES 9.3%, Bi-BES 9.8%, No-BES 7.7%, Pr-CoCr-EES 10.4%, SES 10.2%; overall PAbstract : Objective: Data on the comparative effectiveness of contemporary drug-eluting stents (DES) in the unrestricted, real-world setting are limited. We investigated the long-term effectiveness and safety of contemporary different drug-eluting stents by means of multiple treatment propensity score weighting. Patients and methods: From seven stent-specific, prospective DES registries conducted between July 2007 and July 2015, we evaluated 17 196 patients who received several contemporary DES and first-generation DES: 3053 treated with cobalt–chromium everolimus-eluting stents (CoCr-EES), 2985 with platinum–chromium EES (PtCr-EES), 2922 with Resolute zotarolimus-eluting stents (Re-ZES), 789 with Biomatrix biolimus-eluting stents (Bi-BES), 1907 with Nobori biolimus-eluting stents (No-BES), 1970 with Xience Prime cobalt–chromium everolimus-eluting stents (Pr-CoCr-EES), and 3570 with sirolimus-eluting stents (SES). The primary outcome was target-vessel failure (a composite of cardiac death, target-vessel myocardial infarction, or target-vessel revascularization) at 3 years of follow-up and major cardiovascular adverse events (a composite of all-cause death, any myocardial infarction, or any revascularization) was also evaluated. Results: The observed 3-year rates of target-vessel failure were not significantly different among different second-generation DES and SES (CoCr-EES 9.8%, PtCr-EES 9.5%, Re-ZES 9.3%, Bi-BES 9.8%, No-BES 7.7%, Pr-CoCr-EES 10.4%, SES 10.2%; overall P =0.07). In multiple treatment propensity score analysis, adjusted hazard ratios for target-vessel failure were similar in between-group comparisons of several contemporary DES. In addition, no significant differences were observed with respect of the adjusted risk of major adverse cardiac events. Conclusion: In this comparative effectiveness research using stent-specific, clinical practice registries involving unrestricted use of several contemporary DES, there were no significant between-group differences in the 3-year rates of target-vessel failure. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Coronary artery disease. Volume 30:Issue 4(2019:Jun.)
- Journal:
- Coronary artery disease
- Issue:
- Volume 30:Issue 4(2019:Jun.)
- Issue Display:
- Volume 30, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 4
- Issue Sort Value:
- 2019-0030-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-06
- Subjects:
- coronary artery disease -- drug-eluting stents -- percutaneous coronary intervention
Coronary heart disease -- Periodicals
Coronary Disease -- Indexes
Coronary Disease -- Periodicals
616.123005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00019501-000000000-00000 ↗
http://www.coronary-artery.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MCA.0000000000000730 ↗
- Languages:
- English
- ISSNs:
- 0954-6928
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3472.049000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12841.xml