Frequency-selective non-linear blending for the computed tomography diagnosis of acute gangrenous cholecystitis: Pilot retrospective evaluation. (2018)
- Record Type:
- Journal Article
- Title:
- Frequency-selective non-linear blending for the computed tomography diagnosis of acute gangrenous cholecystitis: Pilot retrospective evaluation. (2018)
- Main Title:
- Frequency-selective non-linear blending for the computed tomography diagnosis of acute gangrenous cholecystitis: Pilot retrospective evaluation
- Authors:
- Schwarz, R.
Bongers, N.M.
Hinterleitner, C.
Ditt, H.
Nikolaou, K.
Fritz, J.
Bösmüller, H.
Horger, M. - Abstract:
- Abstract: Purpose: To compare the diagnostic performance of frequency-selective non-linear blending and conventional linear blending contrast-enhanced CT for the diagnosis of acute (AC) and gangrenous (GC) cholecystitis. Materials and methods: Following local ethics committee approval for retrospective data analysis, a database search derived 39 patients (26 men, mean age 67.8 ± 14.6 years) with clinical signs of acute cholecystitis, contrast enhanced CT (CECT) evaluation, cholecystectomy, and pathological examination of the resected specimen. The interval between CECT and surgery was 4.7 ± 4.1 days. Pathological gross examination was used to categorize the cases into AC and GC. Subsequently, two radiologists categorized the CECT studies in a blinded and independent fashion into AC and GC, during two different reading sessions using linear blending and frequency-selective non-linear blending CECT. Results: Histologic analysis diagnosed 31/39 (79.4%) cases of GC and 8/39 (20.6%) cases of AC. Image interpretation of linear blending CECT resulted in classification of 7/39 (17.9%) patients as GC and 32/39 (82.1%) as AC, whereas image interpretation of frequency-selective non-linear blending CECT resulted in classification of 29/39 (74.3%) patients as GC and 10/39 (25.7%) as AC. Sensitivity/specificity/PPV/NPV for detection of GC were 22.6%/100%/100%/25% with linear blending CECT and 80.6%/50%/86.2%/40% with frequency-selective non-linear blending CECT, respectively. Based on theAbstract: Purpose: To compare the diagnostic performance of frequency-selective non-linear blending and conventional linear blending contrast-enhanced CT for the diagnosis of acute (AC) and gangrenous (GC) cholecystitis. Materials and methods: Following local ethics committee approval for retrospective data analysis, a database search derived 39 patients (26 men, mean age 67.8 ± 14.6 years) with clinical signs of acute cholecystitis, contrast enhanced CT (CECT) evaluation, cholecystectomy, and pathological examination of the resected specimen. The interval between CECT and surgery was 4.7 ± 4.1 days. Pathological gross examination was used to categorize the cases into AC and GC. Subsequently, two radiologists categorized the CECT studies in a blinded and independent fashion into AC and GC, during two different reading sessions using linear blending and frequency-selective non-linear blending CECT. Results: Histologic analysis diagnosed 31/39 (79.4%) cases of GC and 8/39 (20.6%) cases of AC. Image interpretation of linear blending CECT resulted in classification of 7/39 (17.9%) patients as GC and 32/39 (82.1%) as AC, whereas image interpretation of frequency-selective non-linear blending CECT resulted in classification of 29/39 (74.3%) patients as GC and 10/39 (25.7%) as AC. Sensitivity/specificity/PPV/NPV for detection of GC were 22.6%/100%/100%/25% with linear blending CECT and 80.6%/50%/86.2%/40% with frequency-selective non-linear blending CECT, respectively. Based on the histopathologic diagnosis frequency-selective non-linear blending had a significant improvement (p > 0.0001) in the diagnostic accuracy of gangrenous cholecystitis compared with linear blending. Conclusion: Frequency-selective non-linear blending post-processing increases the diagnostic accuracy of gangrenous cholecystitis owing to improved visualization of absence of focal enhancement and mural ulcerations. … (more)
- Is Part Of:
- European journal of radiology open. Volume 5(2018)
- Journal:
- European journal of radiology open
- Issue:
- Volume 5(2018)
- Issue Display:
- Volume 5, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 5
- Issue:
- 2018
- Issue Sort Value:
- 2018-0005-2018-0000
- Page Start:
- 114
- Page End:
- 120
- Publication Date:
- 2018
- Subjects:
- Acute cholecystits -- Gangrenous cholecystits -- Post processing CT imaging -- Frequency selective non linear blending -- Emergency -- CT
Medical radiology -- Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/23520477/ ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.ejro.2018.07.005 ↗
- Languages:
- English
- ISSNs:
- 2352-0477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12853.xml