3D phase contrast MRI: Partial volume correction for robust blood flow quantification in small intracranial vessels. Issue 1 (28th February 2017)
- Record Type:
- Journal Article
- Title:
- 3D phase contrast MRI: Partial volume correction for robust blood flow quantification in small intracranial vessels. Issue 1 (28th February 2017)
- Main Title:
- 3D phase contrast MRI: Partial volume correction for robust blood flow quantification in small intracranial vessels
- Authors:
- Bouillot, Pierre
Delattre, Bénédicte M. A.
Brina, Olivier
Ouared, Rafik
Farhat, Mohamed
Chnafa, Christophe
Steinman, David A.
Lovblad, Karl‐Olof
Pereira, Vitor M.
Vargas, Maria I. - Abstract:
- Abstract : Purpose: Recent advances in 3D‐PCMRI (phase contrast MRI) sequences allow for measuring the complex hemodynamics in cerebral arteries. However, the small size of these vessels vs spatial resolution can lead to non‐negligible partial volume artifacts, which must be taken into account when computing blood flow rates. For this purpose, we combined the velocity information provided by 3D‐PCMRI with vessel geometry measured with 3DTOF (time of flight MRI) or 3DRA (3D rotational angiography) to correct the partial volume effects in flow rate assessments. Methods: The proposed methodology was first tested in vitro on cylindrical and patient specific vessels subject to fully controlled pulsatile flows. Both 2D‐ and 3D‐PCMRI measurements using various spatial resolutions ranging from 20 to 1.3 voxels per vessel diameter were analyzed and compared with flowmeter baseline. Second, 3DTOF, 2D‐ and 3D‐PCMRI measurements were performed in vivo on 35 patients harboring internal carotid artery (ICA) aneurysms indicated for endovascular treatments requiring 3DRA imaging. Results: The in vitro 2D‐ and 3D‐PCMRI mean flow rates assessed with partial volume correction showed very low sensitivity to the acquisition resolution above ≈ 2 voxels per vessel diameter while uncorrected flow rates deviated critically when decreasing the spatial resolution. 3D‐PCMRI flow rates measured in vivo in ICA agreed very well with 2D‐PCMRI data and a good flow conservation was observed at the C7Abstract : Purpose: Recent advances in 3D‐PCMRI (phase contrast MRI) sequences allow for measuring the complex hemodynamics in cerebral arteries. However, the small size of these vessels vs spatial resolution can lead to non‐negligible partial volume artifacts, which must be taken into account when computing blood flow rates. For this purpose, we combined the velocity information provided by 3D‐PCMRI with vessel geometry measured with 3DTOF (time of flight MRI) or 3DRA (3D rotational angiography) to correct the partial volume effects in flow rate assessments. Methods: The proposed methodology was first tested in vitro on cylindrical and patient specific vessels subject to fully controlled pulsatile flows. Both 2D‐ and 3D‐PCMRI measurements using various spatial resolutions ranging from 20 to 1.3 voxels per vessel diameter were analyzed and compared with flowmeter baseline. Second, 3DTOF, 2D‐ and 3D‐PCMRI measurements were performed in vivo on 35 patients harboring internal carotid artery (ICA) aneurysms indicated for endovascular treatments requiring 3DRA imaging. Results: The in vitro 2D‐ and 3D‐PCMRI mean flow rates assessed with partial volume correction showed very low sensitivity to the acquisition resolution above ≈ 2 voxels per vessel diameter while uncorrected flow rates deviated critically when decreasing the spatial resolution. 3D‐PCMRI flow rates measured in vivo in ICA agreed very well with 2D‐PCMRI data and a good flow conservation was observed at the C7 bifurcation. Globally, partial volume correction led to 10–15% lower flow rates than uncorrected values as those reported in most of the published studies on intracranial flows. Conclusion: Partial volume correction may improve the accuracy of PCMRI flow rate measurements especially in small vessels such as intracranial arteries. Magn Reson Med 79:129–140, 2018. © 2017 International Society for Magnetic Resonance in Medicine. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 79:Issue 1(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 79:Issue 1(2018)
- Issue Display:
- Volume 79, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 79
- Issue:
- 1
- Issue Sort Value:
- 2018-0079-0001-0000
- Page Start:
- 129
- Page End:
- 140
- Publication Date:
- 2017-02-28
- Subjects:
- Partial volume correction -- blood flow -- PCMRI -- intracranial arteries
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26637 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12851.xml