Modeling real shim fields for very high degree (and order) B0 shimming of the human brain at 9.4 T. Issue 1 (20th March 2017)
- Record Type:
- Journal Article
- Title:
- Modeling real shim fields for very high degree (and order) B0 shimming of the human brain at 9.4 T. Issue 1 (20th March 2017)
- Main Title:
- Modeling real shim fields for very high degree (and order) B0 shimming of the human brain at 9.4 T
- Authors:
- Chang, Paul
Nassirpour, Sahar
Henning, Anke - Abstract:
- Abstract : Purpose: To describe the process of calibrating a B0 shim system using high‐degree (or high order) spherical harmonic models of the measured shim fields, to provide a method that considers amplitude dependency of these models, and to show the advantage of very high‐degree B0 shimming for whole‐brain and single‐slice applications at 9.4 Tesla (T). Methods: An insert shim with up to fourth and partial fifth/sixth degree (order) spherical harmonics was used with a Siemens 9.4T scanner. Each shim field was measured and modeled as input for the shimming algorithm. Optimal shim currents can therefore be calculated in a single iteration. A range of shim currents was used in the modeling to account for possible amplitude nonlinearities. The modeled shim fields were used to compare different degrees of whole‐brain B0 shimming on healthy subjects. Results: The ideal shim fields did not correctly shim the subject brains. However, using the modeled shim fields improved the B0 homogeneity from 55.1 (second degree) to 44.68 Hz (partial fifth/sixth degree) on the whole brains of 9 healthy volunteers, with a total applied current of 0.77 and 6.8 A, respectively. Conclusions: The necessity of calibrating the shim system was shown. Better B0 homogeneity drastically reduces signal dropout and distortions for echo‐planar imaging, and significantly improves the linewidths of MR spectroscopy imaging. Magn Reson Med 79:529–540, 2018. © 2017 International Society for Magnetic ResonanceAbstract : Purpose: To describe the process of calibrating a B0 shim system using high‐degree (or high order) spherical harmonic models of the measured shim fields, to provide a method that considers amplitude dependency of these models, and to show the advantage of very high‐degree B0 shimming for whole‐brain and single‐slice applications at 9.4 Tesla (T). Methods: An insert shim with up to fourth and partial fifth/sixth degree (order) spherical harmonics was used with a Siemens 9.4T scanner. Each shim field was measured and modeled as input for the shimming algorithm. Optimal shim currents can therefore be calculated in a single iteration. A range of shim currents was used in the modeling to account for possible amplitude nonlinearities. The modeled shim fields were used to compare different degrees of whole‐brain B0 shimming on healthy subjects. Results: The ideal shim fields did not correctly shim the subject brains. However, using the modeled shim fields improved the B0 homogeneity from 55.1 (second degree) to 44.68 Hz (partial fifth/sixth degree) on the whole brains of 9 healthy volunteers, with a total applied current of 0.77 and 6.8 A, respectively. Conclusions: The necessity of calibrating the shim system was shown. Better B0 homogeneity drastically reduces signal dropout and distortions for echo‐planar imaging, and significantly improves the linewidths of MR spectroscopy imaging. Magn Reson Med 79:529–540, 2018. © 2017 International Society for Magnetic Resonance in Medicine. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 79:Issue 1(2018)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 79:Issue 1(2018)
- Issue Display:
- Volume 79, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 79
- Issue:
- 1
- Issue Sort Value:
- 2018-0079-0001-0000
- Page Start:
- 529
- Page End:
- 540
- Publication Date:
- 2017-03-20
- Subjects:
- B0 shimming -- field modeling -- ultrahigh field strengths -- high‐order shimming
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26658 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12851.xml