A subject-specific finite element musculoskeletal framework for mechanics analysis of a total knee replacement. (22nd August 2018)
- Record Type:
- Journal Article
- Title:
- A subject-specific finite element musculoskeletal framework for mechanics analysis of a total knee replacement. (22nd August 2018)
- Main Title:
- A subject-specific finite element musculoskeletal framework for mechanics analysis of a total knee replacement
- Authors:
- Shu, Liming
Yamamoto, Ko
Yao, Jiang
Saraswat, Prabhav
Liu, Yao
Mitsuishi, Mamoru
Sugita, Naohiko - Abstract:
- Abstract: Concurrent use of finite element (FE) and musculoskeletal (MS) modeling techniques is capable of considering the interactions between prosthetic mechanics and subject dynamics after a total knee replacement (TKR) surgery is performed. However, it still has not been performed in terms of favorable prediction accuracy and systematic experimental validation. In this study, we presented a methodology to develop a subject-specific FE-MS model of a human right lower extremity including the interactions among the subject-specific MS model, the knee joint model with ligament bundles, and the deformable FE prosthesis model. In order to evaluate its accuracy, the FE-MS model was compared with a traditional hinge-constraint MS model and experimentally verified over a gait cycle. Both models achieved good temporal agreement between the predicted muscle force and the electromyography results, though the magnitude on models is different. A higher predicted accuracy, quantified by the root-mean-square error ( RMSE ) and the squared Pearson correlation coefficient ( r 2 ), was found in the FE-MS model ( RMSE = 177.2 N, r 2 = 0.90) when compared with the MS model ( RMSE = 224.1 N, r 2 = 0.81) on the total tibiofemoral contact force. The contact mechanics, including the contact area, pressure, and stress were synchronously simulated, and the maximum contact pressure, 22.06 MPa, occurred on the medial side of the tibial insert without exceeding the yield strength of theAbstract: Concurrent use of finite element (FE) and musculoskeletal (MS) modeling techniques is capable of considering the interactions between prosthetic mechanics and subject dynamics after a total knee replacement (TKR) surgery is performed. However, it still has not been performed in terms of favorable prediction accuracy and systematic experimental validation. In this study, we presented a methodology to develop a subject-specific FE-MS model of a human right lower extremity including the interactions among the subject-specific MS model, the knee joint model with ligament bundles, and the deformable FE prosthesis model. In order to evaluate its accuracy, the FE-MS model was compared with a traditional hinge-constraint MS model and experimentally verified over a gait cycle. Both models achieved good temporal agreement between the predicted muscle force and the electromyography results, though the magnitude on models is different. A higher predicted accuracy, quantified by the root-mean-square error ( RMSE ) and the squared Pearson correlation coefficient ( r 2 ), was found in the FE-MS model ( RMSE = 177.2 N, r 2 = 0.90) when compared with the MS model ( RMSE = 224.1 N, r 2 = 0.81) on the total tibiofemoral contact force. The contact mechanics, including the contact area, pressure, and stress were synchronously simulated, and the maximum contact pressure, 22.06 MPa, occurred on the medial side of the tibial insert without exceeding the yield strength of the ultra-high-molecular-weight polyethylene, 24.79 MPa. The approach outlines an accurate knee joint biomechanics analysis and provides an effective method of applying individualized prosthesis design and verification in TKR. … (more)
- Is Part Of:
- Journal of biomechanics. Volume 77(2018)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 77(2018)
- Issue Display:
- Volume 77, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 77
- Issue:
- 2018
- Issue Sort Value:
- 2018-0077-2018-0000
- Page Start:
- 146
- Page End:
- 154
- Publication Date:
- 2018-08-22
- Subjects:
- Concurrent analysis -- Musculoskeletal model -- Biomechanics -- Validation -- Prosthetic knee
Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2018.07.008 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12832.xml