Endoscopic Self-Expandable Metallic Stent Insertion without Fluoroscopic Guidance Is Feasible and Safe for Acute Colonic Obstruction Caused by Colorectal Cancer. (10th January 2020)
- Record Type:
- Journal Article
- Title:
- Endoscopic Self-Expandable Metallic Stent Insertion without Fluoroscopic Guidance Is Feasible and Safe for Acute Colonic Obstruction Caused by Colorectal Cancer. (10th January 2020)
- Main Title:
- Endoscopic Self-Expandable Metallic Stent Insertion without Fluoroscopic Guidance Is Feasible and Safe for Acute Colonic Obstruction Caused by Colorectal Cancer
- Authors:
- Feng, Yadong
Yu, Qian
Li, Ming
Xu, Wei
Zhu, Ye
Liu, Yang
Shi, Ruihua - Other Names:
- Silvestris Nicola Academic Editor.
- Abstract:
- Abstract : Aims . Endoscopic self-expandable metallic stent (SEMS) insertion for acute colonic obstruction caused by colorectal cancer (CRC) is always performed under fluoroscopic guidance. This study evaluated the feasibility and safety of an endoscopic stenting procedure without fluoroscopic guidance. Methods . A total of 36 patients with an acute colonic obstruction caused by CRC underwent endoscopic SEMS insertion using a colonoscope without fluoroscopic guidance, followed by analyses of the technical and clinical success and short-term complications. Results . Total technical success rate and clinical success rate were 91.7% and 86.1%, respectively. The mean procedure time was 21.2 ± 10.3 minutes. There was no stent dislodgement. One case of hematochezia and two cases of tenesmus occurred in patients with left-sided complete obstructions. No other short-term complications occurred. Procedure time, technical success, and clinical success rate were 16.3 ± 9.4 minutes, 93.1%, and 89.6% for left-sided obstructions, respectively, and were 26.8 ± 10.7 minutes, 85.7%, and 71.4% for right-sided obstructions, respectively. For complete obstructions, procedure time, technical success, and clinical success rate were 22.5 ± 8.9 minutes, 90%, and 83.3%, respectively. In the incomplete cases, procedure time, technical success, and clinical success were 13.5 ± 6.7 minutes, 100%, and 100%, respectively. Technical success, clinical success, and short-term complications were not differedAbstract : Aims . Endoscopic self-expandable metallic stent (SEMS) insertion for acute colonic obstruction caused by colorectal cancer (CRC) is always performed under fluoroscopic guidance. This study evaluated the feasibility and safety of an endoscopic stenting procedure without fluoroscopic guidance. Methods . A total of 36 patients with an acute colonic obstruction caused by CRC underwent endoscopic SEMS insertion using a colonoscope without fluoroscopic guidance, followed by analyses of the technical and clinical success and short-term complications. Results . Total technical success rate and clinical success rate were 91.7% and 86.1%, respectively. The mean procedure time was 21.2 ± 10.3 minutes. There was no stent dislodgement. One case of hematochezia and two cases of tenesmus occurred in patients with left-sided complete obstructions. No other short-term complications occurred. Procedure time, technical success, and clinical success rate were 16.3 ± 9.4 minutes, 93.1%, and 89.6% for left-sided obstructions, respectively, and were 26.8 ± 10.7 minutes, 85.7%, and 71.4% for right-sided obstructions, respectively. For complete obstructions, procedure time, technical success, and clinical success rate were 22.5 ± 8.9 minutes, 90%, and 83.3%, respectively. In the incomplete cases, procedure time, technical success, and clinical success were 13.5 ± 6.7 minutes, 100%, and 100%, respectively. Technical success, clinical success, and short-term complications were not differed between lesion locations and degrees. Conclusions . This simple technique is feasible and safe for palliation of acute colonic obstruction caused by CRC. … (more)
- Is Part Of:
- Gastroenterology research and practice. Volume 2020(2020)
- Journal:
- Gastroenterology research and practice
- Issue:
- Volume 2020(2020)
- Issue Display:
- Volume 2020, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 2020
- Issue:
- 2020
- Issue Sort Value:
- 2020-2020-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01-10
- Subjects:
- Gastroenterology -- Periodicals
Digestive organs -- Diseases -- Periodicals
616.33005 - Journal URLs:
- https://www.hindawi.com/journals/grp/ ↗
- DOI:
- 10.1155/2020/6810164 ↗
- Languages:
- English
- ISSNs:
- 1687-6121
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 12826.xml