Prospective study of five-year outcomes and postoperative complications after total temporomandibular joint replacement with two stock prosthetic systems. Issue 1 (January 2020)
- Record Type:
- Journal Article
- Title:
- Prospective study of five-year outcomes and postoperative complications after total temporomandibular joint replacement with two stock prosthetic systems. Issue 1 (January 2020)
- Main Title:
- Prospective study of five-year outcomes and postoperative complications after total temporomandibular joint replacement with two stock prosthetic systems
- Authors:
- Gonzalez-Perez, L.M.
Gonzalez-Perez-Somarriba, B.
Centeno, G.
Vallellano, C.
Montes-Carmona, J.F.
Torres-Carranza, E.
Ambrosiani-Fernandez, J.
Infante-Cossio, P. - Abstract:
- Abstract: To evaluate and compare outcomes and complications associated with reconstruction of the temporomandibular joint (TMJ), we prospectively analysed the data of 70 patients who had their joints replaced with stock prostheses during the period 2004-14 and who had been followed up for five years. We used two types of stock prostheses: the metal-on-metal Christensen system (CS), and the ultra-high-molecular-weight-polyethylene-on-metal Biomet® system (BS). Data were collected at 3, 6, 12, 24, 36, 48, and 60 months postoperatively and compared with preoperative measurements. Five years after the replacement there was an increase in mean (SD) mouth opening from 2.0 (0.6) to 4.0 (0.5 cm) (p = 0.012) in the CS, and from 2.5 (1.0) cm to 4.1 (0.6) cm (p = 0.018) in the BS. The mean (SD) reductions in visual analogue pain scores were from 6.9 (1.6) to 2.0 (1.4) (p = 0.001) in the CS, and 6.5 (1.4) to 1.5 (1.1) (p = 0.001) in the BS. There were no significant differences in improvements in mouth opening or reduction in pain between the two groups. However, there were differences in the number of implants that failed, which led to removal and replacement of 2/14 prostheses in the CS group and 3/77 in the BS group (p = 0.06). The results supported the placement of stock prostheses, as evidenced by a low incidence of complications and adverse events, and a long-term improvement in function and reduction in pain in the TMJ. The BS group had significantly fewer prosthetic failuresAbstract: To evaluate and compare outcomes and complications associated with reconstruction of the temporomandibular joint (TMJ), we prospectively analysed the data of 70 patients who had their joints replaced with stock prostheses during the period 2004-14 and who had been followed up for five years. We used two types of stock prostheses: the metal-on-metal Christensen system (CS), and the ultra-high-molecular-weight-polyethylene-on-metal Biomet® system (BS). Data were collected at 3, 6, 12, 24, 36, 48, and 60 months postoperatively and compared with preoperative measurements. Five years after the replacement there was an increase in mean (SD) mouth opening from 2.0 (0.6) to 4.0 (0.5 cm) (p = 0.012) in the CS, and from 2.5 (1.0) cm to 4.1 (0.6) cm (p = 0.018) in the BS. The mean (SD) reductions in visual analogue pain scores were from 6.9 (1.6) to 2.0 (1.4) (p = 0.001) in the CS, and 6.5 (1.4) to 1.5 (1.1) (p = 0.001) in the BS. There were no significant differences in improvements in mouth opening or reduction in pain between the two groups. However, there were differences in the number of implants that failed, which led to removal and replacement of 2/14 prostheses in the CS group and 3/77 in the BS group (p = 0.06). The results supported the placement of stock prostheses, as evidenced by a low incidence of complications and adverse events, and a long-term improvement in function and reduction in pain in the TMJ. The BS group had significantly fewer prosthetic failures than the CS group. … (more)
- Is Part Of:
- British journal of oral and maxillofacial surgery. Volume 58:Issue 1(2020)
- Journal:
- British journal of oral and maxillofacial surgery
- Issue:
- Volume 58:Issue 1(2020)
- Issue Display:
- Volume 58, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 58
- Issue:
- 1
- Issue Sort Value:
- 2020-0058-0001-0000
- Page Start:
- 69
- Page End:
- 74
- Publication Date:
- 2020-01
- Subjects:
- Temporomandibular joint -- temporomandibular joint replacement -- stock joint prostheses -- metal-on-metal prostheses -- ultra-high-molecular-weight-polyethylene-on-metal prostheses
Mouth -- Surgery -- Periodicals
Maxilla -- Surgery -- Periodicals
Face -- Surgery -- Periodicals
Surgery, Plastic -- Periodicals
Dentistry, Operative -- Periodicals
Face -- surgery -- Periodicals
Mouth -- surgery -- Periodicals
Maxilla -- surgery -- Periodicals
Surgery, Oral -- Periodicals
Oral Surgical Procedures -- Periodicals
Dentistry, Operative -- Periodicals
Bouche -- Chirurgie -- Périodiques
Maxillaire supérieur -- Chirurgie -- Périodiques
Face -- Chirurgie -- Périodiques
Chirurgie dentaire -- Périodiques
Dentistry, Operative
Face -- Surgery
Maxilla -- Surgery
Mouth -- Surgery
Surgery, Plastic
Electronic journals
Periodicals
617.52059 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02664356 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.bjoms.2019.10.312 ↗
- Languages:
- English
- ISSNs:
- 0266-4356
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2314.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12813.xml