Heart rate estimation from wrist-type photoplethysmography signals during physical exercise. (March 2020)
- Record Type:
- Journal Article
- Title:
- Heart rate estimation from wrist-type photoplethysmography signals during physical exercise. (March 2020)
- Main Title:
- Heart rate estimation from wrist-type photoplethysmography signals during physical exercise
- Authors:
- Arunkumar, K.R.
Bhaskar, M. - Abstract:
- Highlights: A robust and computationally efficient de-noising technique that combines three stages of cascaded adaptive filters like RLS, NLMS and LMS has been proposed. The filtered output obtained from the RLS, NLMS and LMS adaptive filters are combined using softmax activation function. The search range (SR), a band of location points from which the HR is estimated, has been selected dynamically by varying the parameter Δ, which depends on the power value of the accelerometer signals. The proposed method delivers less error value when evaluated on 22 datasets each performing different activity. Abstract: Wearable devices, such as smart watch use photoplethysmography (PPG) signals for estimating heart rate (HR). The motion artifacts (MA) contained in these PPG signals lead to an erroneous HR estimation. In this manuscript, a new de-noising algorithm has been proposed that uses the combination of cascaded recursive least square (RLS), normalized least mean square (NLMS) and least mean square (LMS) adaptive filters. The MA reduced PPG signals obtained from these cascaded adaptive filters are combined using the softmax activation function. Fast Fourier transform (FFT) is used to estimate the HR from the MA reduced PPG signals and phase vocoder is used to refine the estimated HR. The performance of the proposed method in the form of mean error, standard deviation of the mean error and mean relative error is analyzed using the 22 datasets given for IEEE Signal processing cupHighlights: A robust and computationally efficient de-noising technique that combines three stages of cascaded adaptive filters like RLS, NLMS and LMS has been proposed. The filtered output obtained from the RLS, NLMS and LMS adaptive filters are combined using softmax activation function. The search range (SR), a band of location points from which the HR is estimated, has been selected dynamically by varying the parameter Δ, which depends on the power value of the accelerometer signals. The proposed method delivers less error value when evaluated on 22 datasets each performing different activity. Abstract: Wearable devices, such as smart watch use photoplethysmography (PPG) signals for estimating heart rate (HR). The motion artifacts (MA) contained in these PPG signals lead to an erroneous HR estimation. In this manuscript, a new de-noising algorithm has been proposed that uses the combination of cascaded recursive least square (RLS), normalized least mean square (NLMS) and least mean square (LMS) adaptive filters. The MA reduced PPG signals obtained from these cascaded adaptive filters are combined using the softmax activation function. Fast Fourier transform (FFT) is used to estimate the HR from the MA reduced PPG signals and phase vocoder is used to refine the estimated HR. The performance of the proposed method in the form of mean error, standard deviation of the mean error and mean relative error is analyzed using the 22 datasets given for IEEE Signal processing cup 2015. This resulted in an error of 1.86 beat per minute (BPM) tested on 22 datasets which is less compared to other existing methods. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 57(2020)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 57(2020)
- Issue Display:
- Volume 57, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 57
- Issue:
- 2020
- Issue Sort Value:
- 2020-0057-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- Photoplethysmography -- Combination of RLS, NLMS and LMS adaptive filters -- Softmax activation function -- Motion artifact -- Fast Fourier transform -- Phase vocoder -- Heart rate estimation
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2019.101790 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12806.xml