Blind, Cuff-less, Calibration-Free and Continuous Blood Pressure Estimation using Optimized Inductive Group Method of Data Handling. (March 2020)
- Record Type:
- Journal Article
- Title:
- Blind, Cuff-less, Calibration-Free and Continuous Blood Pressure Estimation using Optimized Inductive Group Method of Data Handling. (March 2020)
- Main Title:
- Blind, Cuff-less, Calibration-Free and Continuous Blood Pressure Estimation using Optimized Inductive Group Method of Data Handling
- Authors:
- Mohebbian, Mohammad Reza
Dinh, Anh
Wahid, Khan
Alam, Mohammad Sami - Abstract:
- Graphical abstract: Abstract: Traditionally, blood pressure (BP) is measured by cuff-based instruments, which is inconvenient and does not allow continuous measurement. In fact, continuous blood pressure monitoring is precious for gaining information about the health conditions of people. In this paper, an algorithm is developed using a modified group method of data handling technique to estimate systolic BP (SBP) and diastolic BP (DBP) by only photo-plethysmogram (PPG) signal in a continuous manner. The estimation does not require to calibration and is done without any knowledge about significant features, and features are selected based on their competency. The Multi-parameter Intelligent Monitoring in Intensive Care dataset is used for training the system, and the hold-out validation is used in 7 runs by assuming 70% of the samples as a train set. Moreover, a designed hardware device is used for recording data on 25 subjects for testing the trained model on the real-world. As the state-of-the-art, four popular regression algorithms, including support vector machine, adaptive boosting, decision tree and random forest, are trained with conventional features, which use an electrocardiogram (ECG) and PPG signals simultaneously and compared with the proposed system. The root means square error (RMSE) and the mean absolute error (MAE) of the proposed algorithm is 3.47 ± 1.31 and 2.40 ± 1.01 mmHg for SBP and 4.67 ± 1.44 and 3.33 ± 1.61 mmHg for DBP respectively. Also, the RMSEGraphical abstract: Abstract: Traditionally, blood pressure (BP) is measured by cuff-based instruments, which is inconvenient and does not allow continuous measurement. In fact, continuous blood pressure monitoring is precious for gaining information about the health conditions of people. In this paper, an algorithm is developed using a modified group method of data handling technique to estimate systolic BP (SBP) and diastolic BP (DBP) by only photo-plethysmogram (PPG) signal in a continuous manner. The estimation does not require to calibration and is done without any knowledge about significant features, and features are selected based on their competency. The Multi-parameter Intelligent Monitoring in Intensive Care dataset is used for training the system, and the hold-out validation is used in 7 runs by assuming 70% of the samples as a train set. Moreover, a designed hardware device is used for recording data on 25 subjects for testing the trained model on the real-world. As the state-of-the-art, four popular regression algorithms, including support vector machine, adaptive boosting, decision tree and random forest, are trained with conventional features, which use an electrocardiogram (ECG) and PPG signals simultaneously and compared with the proposed system. The root means square error (RMSE) and the mean absolute error (MAE) of the proposed algorithm is 3.47 ± 1.31 and 2.40 ± 1.01 mmHg for SBP and 4.67 ± 1.44 and 3.33 ± 1.61 mmHg for DBP respectively. Also, the RMSE of the proposed algorithm on recorded data by hardware device is 3.2 ± 0.7 and 4.4 ± 1.0 mmHg, and the MAE is 2.2 ± 0.7 and 2.9 ± 1.2 mmHg for SBP and DBP, respectively. The proposed algorithm is not dependent on synchronization of ECG and PPG, and it is promising compared to the state-of-the-art, especially in recorded data by new hardware. … (more)
- Is Part Of:
- Biomedical signal processing and control. Volume 57(2020)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 57(2020)
- Issue Display:
- Volume 57, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 57
- Issue:
- 2020
- Issue Sort Value:
- 2020-0057-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- Continuous Blood Pressure -- Machine learning -- Cuff-less -- Calibration-free -- Blind Regression
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2019.101682 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12806.xml