An efficient removal of power-line interference and baseline wander from ECG signals by employing Fourier decomposition technique. (March 2020)
- Record Type:
- Journal Article
- Title:
- An efficient removal of power-line interference and baseline wander from ECG signals by employing Fourier decomposition technique. (March 2020)
- Main Title:
- An efficient removal of power-line interference and baseline wander from ECG signals by employing Fourier decomposition technique
- Authors:
- Singhal, Amit
Singh, Pushpendra
Fatimah, Binish
Pachori, Ram Bilas - Abstract:
- Abstract: Baseline wander (BW) and power-line interference (PLI) tend to occur in every recorded electrocardiogram (ECG) signal and can significantly deteriorate the quality of the signal. They need to be separated from the ECG signal to facilitate an accurate diagnosis of the patient. In this paper, we propose a new methodology based on the Fourier decomposition method (FDM) to separate both BW and PLI simultaneously from the recorded ECG signal and obtain clean ECG data. The proposed method employs either of discrete Fourier transform (DFT) or discrete cosine transform (DCT) in order to process the signal. Key DFT/DCT coefficients relating to BW and PLI are identified and then suppressed using optimally designed FDM based on a zero-phase filtering approach. The effectiveness of our method is validated on the MIT-BIH Arrhythmia database. Simulation results clearly demonstrate that the proposed method performs superior in comparison to the existing state-of-the-art techniques at different levels of signal to noise ratio power (SNR). Moreover, this method has low computational complexity which makes it suitable for real-time pre-processing of ECG signals.
- Is Part Of:
- Biomedical signal processing and control. Volume 57(2020)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 57(2020)
- Issue Display:
- Volume 57, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 57
- Issue:
- 2020
- Issue Sort Value:
- 2020-0057-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- Baseline wander -- ECG signal -- Noise removal -- Power-line interference -- Fourier decomposition method
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2019.101741 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12806.xml