Transvenous management of cardiac implantable electronic device late lead perforation. (10th January 2020)
- Record Type:
- Journal Article
- Title:
- Transvenous management of cardiac implantable electronic device late lead perforation. (10th January 2020)
- Main Title:
- Transvenous management of cardiac implantable electronic device late lead perforation
- Authors:
- Jessel, Peter M.
Yadava, Mrinal
Nazer, Babak
Dewland, Thomas A.
Miller, Jared
Stecker, Eric C.
Bhamidipati, Castigliano M.
Song, Howard K.
Henrikson, Charles A. - Abstract:
- Abstract: Introduction: Late lead perforation (LLP), defined as perforation ≥30 days from cardiac implantable electronic device implant, is a rare diagnosis and little data exist regarding management practices and outcomes. The purpose of this study was to evaluate the occurrence, safety, and efficacy of transvenous management of clinically significant LLP. Methods: The electronic medical records of a single‐center tertiary hospital were reviewed for all patients who were referred for LLP or its sequelae. Results: Eleven consecutive patients were identified from October 2011 to December 2018 with clinically significant LLP. Patients most often presented with pericardial symptoms with the exception of one asymptomatic patient. The median time from lead implant to intervention for LLP was 246 days. Nine patients were managed with an initial transvenous approach, with one requiring sternotomy (lead 6.3 years old). Two patients had a surgical approach, one performed at an outside hospital with subsequent death and another had a mini‐thoracotomy, but the lead was removed percutaneously with no surgical repair. In this small cohort, there was no association between the lead extending beyond the parietal pericardium and surgical repair ( P = .99). Conclusion: Our single‐center experience suggests that LLP can be initially managed with a cautious transvenous approach in most patients, but intraprocedural ultrasound for pericardial monitoring and a rescue plan with immediateAbstract: Introduction: Late lead perforation (LLP), defined as perforation ≥30 days from cardiac implantable electronic device implant, is a rare diagnosis and little data exist regarding management practices and outcomes. The purpose of this study was to evaluate the occurrence, safety, and efficacy of transvenous management of clinically significant LLP. Methods: The electronic medical records of a single‐center tertiary hospital were reviewed for all patients who were referred for LLP or its sequelae. Results: Eleven consecutive patients were identified from October 2011 to December 2018 with clinically significant LLP. Patients most often presented with pericardial symptoms with the exception of one asymptomatic patient. The median time from lead implant to intervention for LLP was 246 days. Nine patients were managed with an initial transvenous approach, with one requiring sternotomy (lead 6.3 years old). Two patients had a surgical approach, one performed at an outside hospital with subsequent death and another had a mini‐thoracotomy, but the lead was removed percutaneously with no surgical repair. In this small cohort, there was no association between the lead extending beyond the parietal pericardium and surgical repair ( P = .99). Conclusion: Our single‐center experience suggests that LLP can be initially managed with a cautious transvenous approach in most patients, but intraprocedural ultrasound for pericardial monitoring and a rescue plan with immediate surgical back up is mandatory. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 31:Number 2(2020)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 31:Number 2(2020)
- Issue Display:
- Volume 31, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 31
- Issue:
- 2
- Issue Sort Value:
- 2020-0031-0002-0000
- Page Start:
- 521
- Page End:
- 528
- Publication Date:
- 2020-01-10
- Subjects:
- cardiac implantable electronic device -- lead extraction -- lead perforation
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14331 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12805.xml