Trace Arsenic Determination in a TiO2 Pigment Matrix Using Electrothermal Atomic Absorption Spectrometry. (April 2020)
- Record Type:
- Journal Article
- Title:
- Trace Arsenic Determination in a TiO2 Pigment Matrix Using Electrothermal Atomic Absorption Spectrometry. (April 2020)
- Main Title:
- Trace Arsenic Determination in a TiO2 Pigment Matrix Using Electrothermal Atomic Absorption Spectrometry
- Authors:
- Finšgar, Matjaž
Govejšek, Tamara
Gradišek, Ksenija - Abstract:
- This work describes the use of electrothermal atomic absorption spectrometry in combination with a pyrolytic graphite-coated tube with a platform for trace arsenic (As) determination in titanium dioxide (TiO2 ) pigment. This type of matrix is challenging, as complete digestion in hydrofluoric acid-containing solution is needed. First, closed-vessel microwave digestion was performed for the full-sample decomposition. Next, a temperature program was optimized for drying, pyrolysis, and atomization temperatures. Furthermore, the use of a chemical modifier mixture was proposed that reduced the background contribution and prevented significant analyte loss and therefore improved the analytical procedure. The optimized method was validated for the detection (LOD) and quantification (LOQ) limits, the linear concentration range, accuracy, and precision. Special attention was devoted to the matrix-matching solutions in the calibration procedure. Linearity was confirmed in the 5.0 to 100.0 µg/L concentration range ( R 2 = 0.999). The average recovery for 16 different real TiO2 pigment samples was 92.0%, and the relative standard deviation value for six replicate measurements was ≤10.4%. Moreover, the LOD and LOQ in terms of the TiO2 pigment mass was determined to be 0.2 µg/(g TiO2 ) and 0.7 µg/(g TiO2 ), respectively. The latter complies with Commission Directive 2008/128/EC, which does not allow more than 3 µg As/(g product) as the specific criteria of purity. Finally, based onThis work describes the use of electrothermal atomic absorption spectrometry in combination with a pyrolytic graphite-coated tube with a platform for trace arsenic (As) determination in titanium dioxide (TiO2 ) pigment. This type of matrix is challenging, as complete digestion in hydrofluoric acid-containing solution is needed. First, closed-vessel microwave digestion was performed for the full-sample decomposition. Next, a temperature program was optimized for drying, pyrolysis, and atomization temperatures. Furthermore, the use of a chemical modifier mixture was proposed that reduced the background contribution and prevented significant analyte loss and therefore improved the analytical procedure. The optimized method was validated for the detection (LOD) and quantification (LOQ) limits, the linear concentration range, accuracy, and precision. Special attention was devoted to the matrix-matching solutions in the calibration procedure. Linearity was confirmed in the 5.0 to 100.0 µg/L concentration range ( R 2 = 0.999). The average recovery for 16 different real TiO2 pigment samples was 92.0%, and the relative standard deviation value for six replicate measurements was ≤10.4%. Moreover, the LOD and LOQ in terms of the TiO2 pigment mass was determined to be 0.2 µg/(g TiO2 ) and 0.7 µg/(g TiO2 ), respectively. The latter complies with Commission Directive 2008/128/EC, which does not allow more than 3 µg As/(g product) as the specific criteria of purity. Finally, based on scanning electron microscopy analysis of unused and several times used pyrolytic graphite-coated tubes, usage of the tube 250 times before replacement is recommended. … (more)
- Is Part Of:
- SLAS technology. Volume 25:Number 2(2020)
- Journal:
- SLAS technology
- Issue:
- Volume 25:Number 2(2020)
- Issue Display:
- Volume 25, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 25
- Issue:
- 2
- Issue Sort Value:
- 2020-0025-0002-0000
- Page Start:
- 123
- Page End:
- 131
- Publication Date:
- 2020-04
- Subjects:
- trace arsenic -- TiO2 pigment -- chemical modifier -- matrix modifier -- electrothermal atomic absorption spectrometry
Medical laboratory technology -- Periodicals
Laboratories -- Equipment and supplies -- Periodicals
Diagnosis, Laboratory -- Periodicals
616.075 - Journal URLs:
- http://journals.sagepub.com/home/jla ↗
https://www.sciencedirect.com/journal/slas-technology ↗
http://www.sagepublications.com/ ↗
https://www.journals.elsevier.com/slas-technology ↗ - DOI:
- 10.1177/2472630319877378 ↗
- Languages:
- English
- ISSNs:
- 2472-6303
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12780.xml