Outcomes of the Gore Excluder Iliac Branch Endoprosthesis Using Division Branches of the Internal Iliac Artery as Distal Landing Zones. (April 2020)
- Record Type:
- Journal Article
- Title:
- Outcomes of the Gore Excluder Iliac Branch Endoprosthesis Using Division Branches of the Internal Iliac Artery as Distal Landing Zones. (April 2020)
- Main Title:
- Outcomes of the Gore Excluder Iliac Branch Endoprosthesis Using Division Branches of the Internal Iliac Artery as Distal Landing Zones
- Authors:
- D'Oria, Mario
Tenorio, Emanuel R.
Oderich, Gustavo S.
Mendes, Bernardo C.
Kalra, Manju
Shuja, Fahad
Colglazier, Jill J.
DeMartino, Randall R. - Abstract:
- Purpose: To evaluate the outcomes of the Gore Excluder Iliac Branch Endoprosthesis (IBE) using division branches of the internal iliac artery (IIA) as distal landing zones.Materials and Methods: Between January 1, 2014, and December 31, 2018, 74 patients (mean age 74±7 years; 72 men) treated for aortoiliac or common iliac artery aneurysms had an IBE deployed with distal landing of the side branch within the main trunk (n=60) of the internal iliac artery (IIA) vs within a division branch (n=25). Thirteen (17%) patients received bilateral IBE implantations for a total of 85 vessels evaluated. Early endpoints were technical success, 30-day mortality, 30-day major adverse events (MAEs), and 30-day major access complications. Late endpoints were survival, primary and secondary IIA patency, freedom from IIA branch instability, freedom from new-onset buttock claudication, and aneurysm sac diameter changes. Time-dependent outcomes were reported as Kaplan-Meier curves with differences assessed using the log-rank test. Estimates are presented with the 95% confidence interval (CI).Results: The overall technical success rate was 97%, with 1 technical failure per group (p=0.43). Two patients, one from each group, died within 30 days (p=0.43). No significant differences were seen in the rates of 30-day MAEs (7% vs 17%, p=0.35) or major access complications (9% vs 11%, p>0.99) for patients receiving distal landing in the main trunk vs a division branch, respectively. The mean follow-up forPurpose: To evaluate the outcomes of the Gore Excluder Iliac Branch Endoprosthesis (IBE) using division branches of the internal iliac artery (IIA) as distal landing zones.Materials and Methods: Between January 1, 2014, and December 31, 2018, 74 patients (mean age 74±7 years; 72 men) treated for aortoiliac or common iliac artery aneurysms had an IBE deployed with distal landing of the side branch within the main trunk (n=60) of the internal iliac artery (IIA) vs within a division branch (n=25). Thirteen (17%) patients received bilateral IBE implantations for a total of 85 vessels evaluated. Early endpoints were technical success, 30-day mortality, 30-day major adverse events (MAEs), and 30-day major access complications. Late endpoints were survival, primary and secondary IIA patency, freedom from IIA branch instability, freedom from new-onset buttock claudication, and aneurysm sac diameter changes. Time-dependent outcomes were reported as Kaplan-Meier curves with differences assessed using the log-rank test. Estimates are presented with the 95% confidence interval (CI).Results: The overall technical success rate was 97%, with 1 technical failure per group (p=0.43). Two patients, one from each group, died within 30 days (p=0.43). No significant differences were seen in the rates of 30-day MAEs (7% vs 17%, p=0.35) or major access complications (9% vs 11%, p>0.99) for patients receiving distal landing in the main trunk vs a division branch, respectively. The mean follow-up for the entire cohort was 19±12 months. The overall 1-year survival rate was 94% (95% CI 74% to 99%). The primary and secondary patency rates at 1 year were 98% (95% CI 88% to 99%) vs 95% (95% CI 72% to 99%, p=0.72) and 98% (95% CI 88% to 99%) vs 100% (p=0.41) for the main trunk vs division branch groups, respectively. Freedom from IIA branch instability estimates were also similar at 1-year follow-up [93% (95% CI 82% to 97%) vs 90% (95% CI 66% to 97%), p=0.29], as were the freedom from new-onset buttock claudication estimates [98% (95% CI 86% to 99%) and 94% (95% CI 67% to 99%), respectively; p=0.62]. Mean sac diameter change was 5.4±5.3 mm, not significantly different between the groups (p=0.85).Conclusion: Use of the posterior or anterior division of the IIA as a distal landing zone for the Gore Excluder IBE was safe and efficacious in the midterm. This technique may permit extending indications for endovascular repair of aortoiliac aneurysms to cases with unsuitable anatomy within the IIA main trunk. Long-term assessment is needed to affirm the efficacy of this technique. … (more)
- Is Part Of:
- Journal of endovascular therapy. Volume 27:Number 2(2020:Apr.)
- Journal:
- Journal of endovascular therapy
- Issue:
- Volume 27:Number 2(2020:Apr.)
- Issue Display:
- Volume 27, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 27
- Issue:
- 2
- Issue Sort Value:
- 2020-0027-0002-0000
- Page Start:
- 316
- Page End:
- 327
- Publication Date:
- 2020-04
- Subjects:
- aortoiliac aneurysms -- distal landing zone -- endovascular aneurysm repair -- iliac branch devices -- internal iliac artery
Blood-vessels -- Endoscopic surgery -- Periodicals
Angioscopy -- Periodicals
Intravenous catheterization -- Periodicals
Peripheral vascular diseases -- Treatment -- Periodicals
Vascular Surgical Procedures -- Periodicals
Angioscopy -- Periodicals
Catheterization, Peripheral -- Periodicals
Peripheral Vascular Diseases -- therapy -- Periodicals
Angioscopie
Maladies vasculaires périphériques
617.413 - Journal URLs:
- http://jet.sagepub.com/ ↗
http://www.jevt.org ↗
http://www.uk.sagepub.com ↗ - DOI:
- 10.1177/1526602820905583 ↗
- Languages:
- English
- ISSNs:
- 1526-6028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12771.xml