Interlaboratory comparison of heavy metal testing in animal diagnostic specimens and feed using inductively coupled plasma–mass spectrometry. (March 2020)
- Record Type:
- Journal Article
- Title:
- Interlaboratory comparison of heavy metal testing in animal diagnostic specimens and feed using inductively coupled plasma–mass spectrometry. (March 2020)
- Main Title:
- Interlaboratory comparison of heavy metal testing in animal diagnostic specimens and feed using inductively coupled plasma–mass spectrometry
- Authors:
- McGeehan, Steven
Baszler, Timothy
Gaskill, Cynthia
Johnson, Joseph
Smith, Lori
Raisbeck, Merl
Schrier, Nick
Harris, Heather
Talcott, Patricia - Other Names:
- Uzal Francisco A. guest-editor.
Navarro Mauricio A. guest-editor.
Hostetter Jesse M. guest-editor. - Abstract:
- We compared inductively coupled plasma–mass spectrometry (ICP-MS) test results for the analysis of heavy metals (As, Ba, Cd, Hg, Pb, and Se) in pet foods and routine veterinary diagnostic specimens using intralaboratory and interlaboratory comparisons. Four laboratories, 1 principal laboratory and 3 collaborating laboratories, conducted instrument comparison (limit of detection [LOD], limit of quantification [LOQ], and linear dynamic range [LDR] on 24 data sets), in-house method comparison (accuracy and precision on 120 data sets), and interlaboratory comparison (reproducibility on 528 data sets using Horwitz equation analysis). Matrices tested included 2 types of pet food jerky treats (chicken and sweet potato), bovine blood, and bovine liver and kidney. The instrument comparison study confirmed that ICP-MS provided the sensitivity necessary for the analysis of all heavy metals tested at concentrations below the level of concern for routine diagnostic testing. The "in-house" method comparison samples, spiked at low (0.04 µg/g), medium (0.4 µg/g), and high (8.0 µg/g; note: the high validation level spike for mercury was 2 µg/g) concentration levels, indicated that ICP-MS can meet U.S. FDA acceptance criteria for both accuracy (90–105% recovery) and precision (< 6% coefficient of variation). The interlaboratory comparison studies showed that ICP-MS is a reproducible method for the analysis of heavy metals (HorRat value of 0.5–2.0) except for mercury in one laboratory, whichWe compared inductively coupled plasma–mass spectrometry (ICP-MS) test results for the analysis of heavy metals (As, Ba, Cd, Hg, Pb, and Se) in pet foods and routine veterinary diagnostic specimens using intralaboratory and interlaboratory comparisons. Four laboratories, 1 principal laboratory and 3 collaborating laboratories, conducted instrument comparison (limit of detection [LOD], limit of quantification [LOQ], and linear dynamic range [LDR] on 24 data sets), in-house method comparison (accuracy and precision on 120 data sets), and interlaboratory comparison (reproducibility on 528 data sets using Horwitz equation analysis). Matrices tested included 2 types of pet food jerky treats (chicken and sweet potato), bovine blood, and bovine liver and kidney. The instrument comparison study confirmed that ICP-MS provided the sensitivity necessary for the analysis of all heavy metals tested at concentrations below the level of concern for routine diagnostic testing. The "in-house" method comparison samples, spiked at low (0.04 µg/g), medium (0.4 µg/g), and high (8.0 µg/g; note: the high validation level spike for mercury was 2 µg/g) concentration levels, indicated that ICP-MS can meet U.S. FDA acceptance criteria for both accuracy (90–105% recovery) and precision (< 6% coefficient of variation). The interlaboratory comparison studies showed that ICP-MS is a reproducible method for the analysis of heavy metals (HorRat value of 0.5–2.0) except for mercury in one laboratory, which used a different sample preparation method (open block rather than microwave digestion). Overall, our study showed that ICP-MS is a reproducible method for the analysis of heavy metals in spite of minor differences in methodology. … (more)
- Is Part Of:
- Journal of veterinary diagnostic investigation. Volume 32:Number 2(2020:Mar.)
- Journal:
- Journal of veterinary diagnostic investigation
- Issue:
- Volume 32:Number 2(2020:Mar.)
- Issue Display:
- Volume 32, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2020-0032-0002-0000
- Page Start:
- 291
- Page End:
- 300
- Publication Date:
- 2020-03
- Subjects:
- animal diagnostic specimens -- animal feeds -- heavy metals -- inductively coupled plasma–mass spectrometry -- interlaboratory comparison
Veterinary medicine -- Diagnosis -- Periodicals
636.0896075 - Journal URLs:
- http://vdi.sagepub.com/ ↗
http://online.sagepub.com/ ↗ - DOI:
- 10.1177/1040638720903115 ↗
- Languages:
- English
- ISSNs:
- 1040-6387
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 12771.xml