Analysis of the time-velocity curve in phase-contrast magnetic resonance imaging: a phantom study. (7th October 2019)
- Record Type:
- Journal Article
- Title:
- Analysis of the time-velocity curve in phase-contrast magnetic resonance imaging: a phantom study. (7th October 2019)
- Main Title:
- Analysis of the time-velocity curve in phase-contrast magnetic resonance imaging: a phantom study
- Authors:
- Park, Jieun
Kim, Junghun
Chang, Yongmin
Youn, Sung Won
Lee, Hui Joong
Kang, Eun-Ju
Lee, Ki-Nam
Suchánek, Vojtěch
Hyun, Sinjae
Lee, Jongmin - Abstract:
- Abstract: The aim of this study was to analyze the characteristics of time-velocity curve acquired by phase-contrast magnetic resonance imaging (PC-MRI) using an in-vitro flow model as a reference for hemodynamic studies. The time- velocity curves of the PC-MRI were compared with Doppler ultrasonography (US) and also compared with those obtained in the electromagnetic flowmeter. The correlation between techniques was analyzed using an electromagnetic flowmeter as a reference standard; the maximum, minimum, and average velocities, full-width at half-maximum (FWHM), and ascending gradient (AG) were measured from time-velocity curves. The correlations between an electromagnetic flowmeter and the respective measurement technique for the PC-MRI and Doppler US were found to be high (mean R 2 > 0.9, p < 0.05). These results indicate that these measurement techniques are useful for measuring blood flow information and reflect actual flow. The PC-MRI was the best fit for the minimum velocity and FWHM, and the maximum velocity and AG were the best fit for Doppler US. The PC-MRI showed lower maximum velocity value and higher minimum velocity value than Doppler US. Therefore, PC-MRI demonstrates more obtuse time-velocity curve than Doppler US. In addition, the time- velocity curve of PC-MRI could be calibrated by introducing formulae that can convert each measurement value to a reference standard value within a 10% error. The PC-MRI can be used to estimate the Doppler US using thisAbstract: The aim of this study was to analyze the characteristics of time-velocity curve acquired by phase-contrast magnetic resonance imaging (PC-MRI) using an in-vitro flow model as a reference for hemodynamic studies. The time- velocity curves of the PC-MRI were compared with Doppler ultrasonography (US) and also compared with those obtained in the electromagnetic flowmeter. The correlation between techniques was analyzed using an electromagnetic flowmeter as a reference standard; the maximum, minimum, and average velocities, full-width at half-maximum (FWHM), and ascending gradient (AG) were measured from time-velocity curves. The correlations between an electromagnetic flowmeter and the respective measurement technique for the PC-MRI and Doppler US were found to be high (mean R 2 > 0.9, p < 0.05). These results indicate that these measurement techniques are useful for measuring blood flow information and reflect actual flow. The PC-MRI was the best fit for the minimum velocity and FWHM, and the maximum velocity and AG were the best fit for Doppler US. The PC-MRI showed lower maximum velocity value and higher minimum velocity value than Doppler US. Therefore, PC-MRI demonstrates more obtuse time-velocity curve than Doppler US. In addition, the time- velocity curve of PC-MRI could be calibrated by introducing formulae that can convert each measurement value to a reference standard value within a 10% error. The PC-MRI can be used to estimate the Doppler US using this formula. … (more)
- Is Part Of:
- Computer assisted surgery. Volume 24(2019)Supplement 2
- Journal:
- Computer assisted surgery
- Issue:
- Volume 24(2019)Supplement 2
- Issue Display:
- Volume 24, Issue 2 (2019)
- Year:
- 2019
- Volume:
- 24
- Issue:
- 2
- Issue Sort Value:
- 2019-0024-0002-0000
- Page Start:
- 3
- Page End:
- 12
- Publication Date:
- 2019-10-07
- Subjects:
- Pulsatile flow -- time-velocity curve -- flow analysis -- phase-contrast magnetic resonance imaging -- doppler ultrasonography
Computer-assisted surgery -- Periodicals - Journal URLs:
- http://www.tandfonline.com/ ↗
- DOI:
- 10.1080/24699322.2019.1649066 ↗
- Languages:
- English
- ISSNs:
- 2469-9322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12761.xml