Complications of Bioabsorbable Tibial Interference Screws After Anterior Cruciate Ligament Reconstruction in Pediatric and Adolescent Athletes. Issue 2 (26th February 2020)
- Record Type:
- Journal Article
- Title:
- Complications of Bioabsorbable Tibial Interference Screws After Anterior Cruciate Ligament Reconstruction in Pediatric and Adolescent Athletes. Issue 2 (26th February 2020)
- Main Title:
- Complications of Bioabsorbable Tibial Interference Screws After Anterior Cruciate Ligament Reconstruction in Pediatric and Adolescent Athletes
- Authors:
- Kramer, Dennis E.
Kalish, Leslie A.
Kocher, Mininder S.
Yen, Yi-Meng
Micheli, Lyle J.
Heyworth, Benton E. - Abstract:
- Background: Interference screw fixation using bioabsorbable implants has become the most common form of tibial-sided graft fixation in anterior cruciate ligament reconstruction (ACLR). Complications related to implant use in the pediatric and adolescent population have not been well studied. Purpose/Hypothesis: The purpose of this study was to retrospectively analyze the complications associated with tibial bioabsorbable interference screw use in adolescents after ACLR. We hypothesized that complication rates would be low (<5%) and that different screw types would have similar complication rates and clinical outcomes. Study Design: Case series; Level of evidence, 4. Methods: Included in this study were patients aged ≤18 years who underwent ACLR with a bioabsorbable tibial interference screw between 2000 and 2011 at a single institution. The subpopulation with screw-related symptoms or complications were identified through chart review. The following 2 outcomes were considered: screw-related symptoms and secondary surgery related to the screw. Multivariable logistic regression was used for adjusted analysis of any screw-related problem. Results: There were 925 ACLR procedures in 858 patients (mean age, 15.7 years; range, 10-18 years) who met inclusion criteria. The median follow-up period was 32.0 months. Of the 925 knees, 89 (9.6%) developed a screw-related problem. In 44 (4.8%) cases, no surgery was required; in 45 (4.9%) cases, surgery for a screw-related problem occurredBackground: Interference screw fixation using bioabsorbable implants has become the most common form of tibial-sided graft fixation in anterior cruciate ligament reconstruction (ACLR). Complications related to implant use in the pediatric and adolescent population have not been well studied. Purpose/Hypothesis: The purpose of this study was to retrospectively analyze the complications associated with tibial bioabsorbable interference screw use in adolescents after ACLR. We hypothesized that complication rates would be low (<5%) and that different screw types would have similar complication rates and clinical outcomes. Study Design: Case series; Level of evidence, 4. Methods: Included in this study were patients aged ≤18 years who underwent ACLR with a bioabsorbable tibial interference screw between 2000 and 2011 at a single institution. The subpopulation with screw-related symptoms or complications were identified through chart review. The following 2 outcomes were considered: screw-related symptoms and secondary surgery related to the screw. Multivariable logistic regression was used for adjusted analysis of any screw-related problem. Results: There were 925 ACLR procedures in 858 patients (mean age, 15.7 years; range, 10-18 years) who met inclusion criteria. The median follow-up period was 32.0 months. Of the 925 knees, 89 (9.6%) developed a screw-related problem. In 44 (4.8%) cases, no surgery was required; in 45 (4.9%) cases, surgery for a screw-related problem occurred at a median of 24 months postoperatively. The most common surgical indication was pain at the tibial screw site (42/45, 93%), followed by intra-articular screw issues (3/45, 7%). In adjusted analysis, ACLR procedure performed by a "low-volume" ACL surgeon was the only significant predictor identified. After screw removal surgery, 25 of 27 (93%) patients with at least 12 months of follow-up had complete resolution of screw site symptoms, 18 of 23 (78%) evaluable patients returned to sports, while 8 of 27 (30%) patients underwent additional surgeries, 7 of which were unrelated to the screw procedure. Conclusion: The rate of clinical sequelae from bioabsorbable tibial interference screws was surprisingly high, with symptoms arising after approximately 1 of 10 ACLRs in adolescents. Reoperation for these symptoms was performed in approximately 5% of the knees in the study, at a median 2 years postoperatively. Most patients were able to return to sports after screw removal surgery. … (more)
- Is Part Of:
- Orthopaedic journal of sports medicine. Volume 8:Issue 2(2020)
- Journal:
- Orthopaedic journal of sports medicine
- Issue:
- Volume 8:Issue 2(2020)
- Issue Display:
- Volume 8, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 8
- Issue:
- 2
- Issue Sort Value:
- 2020-0008-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-02-26
- Subjects:
- knee -- ACL -- pediatric sports medicine -- tibial screw
Sports medicine -- Periodicals
Orthopedics -- Periodicals
Arthroscopy -- Periodicals
Arthroplasty -- Periodicals
Knee -- Surgery -- Periodicals
616.7 - Journal URLs:
- http://www.sagepublications.com/ ↗
- DOI:
- 10.1177/2325967120904010 ↗
- Languages:
- English
- ISSNs:
- 2325-9671
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12749.xml