Anatomic and Biomechanical Comparison of the Classic and Congruent-Arc Techniques of the Latarjet Procedure. Issue 3 (31st March 2017)
- Record Type:
- Journal Article
- Title:
- Anatomic and Biomechanical Comparison of the Classic and Congruent-Arc Techniques of the Latarjet Procedure. Issue 3 (31st March 2017)
- Main Title:
- Anatomic and Biomechanical Comparison of the Classic and Congruent-Arc Techniques of the Latarjet Procedure
- Authors:
- Montgomery, Scott R.
Katthagen, Jan Christoph
Mikula, Jacob D.
Marchetti, Daniel C.
Tahal, Dimitri S.
Dornan, Grant
Dahl, Kimi
Brady, Alex
Turnbull, Travis L.
Millett, Peter J. - Abstract:
- Objectives: The Latarjet procedure is commonly performed using either the classic (standing) or the congruent-arc (lying) technique. There are potential clinical advantages and disadvantages of each technique. However, the anatomic and biomechanical effects, benefits, and limitations of each technique are unknown. The purpose of this study was to compare the anatomy and biomechanical strength of fixation between the two techniques. Methods: A biomechanical cadaver study was performed with 20 pairs of male and female shoulders (n=40). One of each pair of shoulders was randomly assigned to receive the classic or congruent-arc technique. Coracoid and glenoid anatomic measurements were collected prior to biomechanical testing. A pull force was applied through the conjoined tendon to replicate forces experienced by the coracoid graft in the early post-operative period, and the failure load was determined for each specimen (Figure 1 ). Figure 1. A-B) Failure of classic technique specimen. C-E) Failure of congruent-arc specimen with gross motion (C-D) occurring before complete failure. To address the primary hypothesis of this study, the strength of each Latarjet technique was assessed while accounting for the size and density of individual coracoid specimens. Mixed-effects ANOVA models were built to assess the effect of Latarjet technique (repeated measures on paired specimens) on failure load and load-to-first motion, adjusted for gender. An a priori power analysis indicated thatObjectives: The Latarjet procedure is commonly performed using either the classic (standing) or the congruent-arc (lying) technique. There are potential clinical advantages and disadvantages of each technique. However, the anatomic and biomechanical effects, benefits, and limitations of each technique are unknown. The purpose of this study was to compare the anatomy and biomechanical strength of fixation between the two techniques. Methods: A biomechanical cadaver study was performed with 20 pairs of male and female shoulders (n=40). One of each pair of shoulders was randomly assigned to receive the classic or congruent-arc technique. Coracoid and glenoid anatomic measurements were collected prior to biomechanical testing. A pull force was applied through the conjoined tendon to replicate forces experienced by the coracoid graft in the early post-operative period, and the failure load was determined for each specimen (Figure 1 ). Figure 1. A-B) Failure of classic technique specimen. C-E) Failure of congruent-arc specimen with gross motion (C-D) occurring before complete failure. To address the primary hypothesis of this study, the strength of each Latarjet technique was assessed while accounting for the size and density of individual coracoid specimens. Mixed-effects ANOVA models were built to assess the effect of Latarjet technique (repeated measures on paired specimens) on failure load and load-to-first motion, adjusted for gender. An a priori power analysis indicated that 20 specimen pairs would be sufficient to detect an effect size of f=0.33 with 80% power. Results: The mean surface area available for fixation in the classic technique was 263.3 mm 2 compared to 177.0 mm 2 in the congruent-arc group (p<0.001). In the classic group, 36% of the glenoid width was re-created, and 50% was re-created in the congruent-arc group (p<0.001). The congruent-arc technique resulted in a significantly lower (p=0.005) mean failure load (238.9 ± 91.2 N) compared to the classic technique (303.0 ± 114 N). Failure load was significantly higher in males (p=0.037); male specimens had a mean failure load of 343.9 ± 122.2 N for the classic technique and 289.4 ± 73.0 N for the congruent-arc technique, and females had a mean failure load of 266.1 ± 97.7 and 193.5 ± 84.0 N, respectively (Figure 2 ). Figure 2. Failure load and load-to-first motion means and standard deviations by technique and gender. Conclusion: In this biomechanical model, the classic technique of the Latarjet procedure provided a greater surface area for healing to the glenoid and greater biomechanical strength of fixation when compared to the congruent-arc technique. The congruent-arc technique allowed restoration of a larger glenoid defect. … (more)
- Is Part Of:
- Orthopaedic journal of sports medicine. Volume 5:Issue 3(2017:Mar.)Supplement 3
- Journal:
- Orthopaedic journal of sports medicine
- Issue:
- Volume 5:Issue 3(2017:Mar.)Supplement 3
- Issue Display:
- Volume 5, Issue 3, Part 3 (2017)
- Year:
- 2017
- Volume:
- 5
- Issue:
- 3
- Part:
- 3
- Issue Sort Value:
- 2017-0005-0003-0003
- Page Start:
- Page End:
- Publication Date:
- 2017-03-31
- Subjects:
- Sports medicine -- Periodicals
Orthopedics -- Periodicals
Arthroscopy -- Periodicals
Arthroplasty -- Periodicals
Knee -- Surgery -- Periodicals
616.7 - Journal URLs:
- http://www.sagepublications.com/ ↗
- DOI:
- 10.1177/2325967117S00114 ↗
- Languages:
- English
- ISSNs:
- 2325-9671
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12732.xml