Cardiac Resynchronization Therapy Using Quadripolar Versus Non‐Quadripolar Left Ventricular Leads Programmed to Biventricular Pacing With Single‐Site Left Ventricular Pacing: Impact on Survival and Heart Failure Hospitalization. Issue 10 (17th October 2017)
- Record Type:
- Journal Article
- Title:
- Cardiac Resynchronization Therapy Using Quadripolar Versus Non‐Quadripolar Left Ventricular Leads Programmed to Biventricular Pacing With Single‐Site Left Ventricular Pacing: Impact on Survival and Heart Failure Hospitalization. Issue 10 (17th October 2017)
- Main Title:
- Cardiac Resynchronization Therapy Using Quadripolar Versus Non‐Quadripolar Left Ventricular Leads Programmed to Biventricular Pacing With Single‐Site Left Ventricular Pacing: Impact on Survival and Heart Failure Hospitalization
- Authors:
- Leyva, Francisco
Zegard, Abbasin
Qiu, Tian
Acquaye, Edmund
Ferrante, Gaetano
Walton, Jamie
Marshall, Howard - Abstract:
- Abstract : Background: In cardiac resynchronization therapy (CRT), quadripolar (QUAD) left ventricular (LV) leads are less prone to postoperative complications than non‐QUAD leads. Some studies have suggested better clinical outcomes. Methods and Results: Clinical events were assessed in 847 patients after CRT‐pacing or CRT‐defibrillation using either QUAD (n=287) or non‐QUAD (n=560), programmed to single‐site site LV pacing. Over a follow‐up period of 3.2 years (median [interquartile range, 1.90–5.0]), QUAD was associated with a lower total mortality (adjusted hazard ratio [aHR]: 0.32, 95% confidence interval [CI], 0.20–0.52), cardiac mortality (aHR: 0.36, 95% CI, 0.20–0.65), and heart failure (HF) hospitalization (aHR: 0.62, 95% CI, 0.39–0.99), after adjustment for age, sex, New York Heart Association class, HF etiology, device type (CRT‐pacing or CRT‐defibrillation), comorbidities, atrial rhythm, medication, left ventricular ejection fraction, and creatinine. Death from pump failure was lower with QUAD (aHR: 0.33; 95% CI, 0.18–0.62), but no group differences emerged with respect to sudden cardiac death. There were no differences in implant‐related complications. Re‐interventions for LV displacement or phrenic nerve stimulation, which were lower with QUAD, predicted total mortality (aHR: 1.68, 95% CI, 1.11–2.54), cardiac mortality (aHR: 2.61, 95% CI, 1.66–4.11) and HF hospitalization (aHR: 2.09, 95% CI, 1.22–3.58). Conclusions: CRT using QUAD, programmed to biventricularAbstract : Background: In cardiac resynchronization therapy (CRT), quadripolar (QUAD) left ventricular (LV) leads are less prone to postoperative complications than non‐QUAD leads. Some studies have suggested better clinical outcomes. Methods and Results: Clinical events were assessed in 847 patients after CRT‐pacing or CRT‐defibrillation using either QUAD (n=287) or non‐QUAD (n=560), programmed to single‐site site LV pacing. Over a follow‐up period of 3.2 years (median [interquartile range, 1.90–5.0]), QUAD was associated with a lower total mortality (adjusted hazard ratio [aHR]: 0.32, 95% confidence interval [CI], 0.20–0.52), cardiac mortality (aHR: 0.36, 95% CI, 0.20–0.65), and heart failure (HF) hospitalization (aHR: 0.62, 95% CI, 0.39–0.99), after adjustment for age, sex, New York Heart Association class, HF etiology, device type (CRT‐pacing or CRT‐defibrillation), comorbidities, atrial rhythm, medication, left ventricular ejection fraction, and creatinine. Death from pump failure was lower with QUAD (aHR: 0.33; 95% CI, 0.18–0.62), but no group differences emerged with respect to sudden cardiac death. There were no differences in implant‐related complications. Re‐interventions for LV displacement or phrenic nerve stimulation, which were lower with QUAD, predicted total mortality (aHR: 1.68, 95% CI, 1.11–2.54), cardiac mortality (aHR: 2.61, 95% CI, 1.66–4.11) and HF hospitalization (aHR: 2.09, 95% CI, 1.22–3.58). Conclusions: CRT using QUAD, programmed to biventricular pacing with single‐site LV pacing, is associated with a lower total mortality, cardiac mortality, and HF hospitalization. These trends were observed for both CRT‐defibrillation and CRT‐pacing, after adjustment for HF cause and other confounders. Re‐intervention for LV lead displacement or phrenic nerve stimulation was associated with worse outcomes. … (more)
- Is Part Of:
- Journal of the American Heart Association. Volume 6:Issue 10(2017)
- Journal:
- Journal of the American Heart Association
- Issue:
- Volume 6:Issue 10(2017)
- Issue Display:
- Volume 6, Issue 10 (2017)
- Year:
- 2017
- Volume:
- 6
- Issue:
- 10
- Issue Sort Value:
- 2017-0006-0010-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2017-10-17
- Subjects:
- arrhythmia -- bipolar lead -- cardiac resynchronization therapy -- heart failure -- quadripolar lead -- sudden cardiac death
Heart -- Diseases -- Periodicals
Cardiovascular system -- Diseases -- Periodicals
Cerebrovascular disease -- Periodicals
Cardiology -- Periodicals
616.1 - Journal URLs:
- http://jaha.ahajournals.org ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2047-9980 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1161/JAHA.117.007026 ↗
- Languages:
- English
- ISSNs:
- 2047-9980
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12733.xml