Assessment of Interobserver Variability for CT Scan–Based Evaluation of Posterior Ligament Complex Injury in Thoracolumbar Fractures: An International Multicenter Pilot Study. Issue 2 (April 2020)
- Record Type:
- Journal Article
- Title:
- Assessment of Interobserver Variability for CT Scan–Based Evaluation of Posterior Ligament Complex Injury in Thoracolumbar Fractures: An International Multicenter Pilot Study. Issue 2 (April 2020)
- Main Title:
- Assessment of Interobserver Variability for CT Scan–Based Evaluation of Posterior Ligament Complex Injury in Thoracolumbar Fractures: An International Multicenter Pilot Study
- Authors:
- Maheswaran, Anupama
Aiyer, Siddharth N.
Farouk, Osama
El-Sharkawi, Mohammad
Park, Jong-Beom
O'Brien, Andrew
Oluwole, Ige
Wang, Yue
Arruda, André de Oliveira
Rajasekaran, Shanmuganathan - Abstract:
- Study Design: A multicenter, pilot study, for radiological assessment of thoracolumbar spine fractures was performed with the participation of 7 centers in Africa, Europe, Asia, and South America as a part of the AO Foundation network. Objectives: To determine the interobserver variability for computed tomography (CT) scan–based evaluation of posterior ligament complex (PLC) injury in thoracolumbar fractures. Methods: Forty-two observers including 1 principal investigator at each participating center performed variability assessment. Each center contributed toward a total of 91 patient images with A3 or A4 thoracolumbar burst fractures (T11-L2) with or without suspected PLC injury. Pathological fractures, multilevel injuries, obvious posterior bony element injury and translation/dislocation injuries were excluded. Ten patients were randomly selected and commonly reported CT parameters indicating PLC injury, including superior inferior endplate angle, vertebral body height loss, local kyphotic deformity, interspinous distance and interpedicular distance were assessed for variability. Observer values were compared with an experienced gold rater in spinal trauma. Analysis of variability was performed for all observers, between the principal investigators and also between observers participating in each center. Results: The studied parameters showed considerable variability in measurements among all observers and amongst all participating centers. The variability between theStudy Design: A multicenter, pilot study, for radiological assessment of thoracolumbar spine fractures was performed with the participation of 7 centers in Africa, Europe, Asia, and South America as a part of the AO Foundation network. Objectives: To determine the interobserver variability for computed tomography (CT) scan–based evaluation of posterior ligament complex (PLC) injury in thoracolumbar fractures. Methods: Forty-two observers including 1 principal investigator at each participating center performed variability assessment. Each center contributed toward a total of 91 patient images with A3 or A4 thoracolumbar burst fractures (T11-L2) with or without suspected PLC injury. Pathological fractures, multilevel injuries, obvious posterior bony element injury and translation/dislocation injuries were excluded. Ten patients were randomly selected and commonly reported CT parameters indicating PLC injury, including superior inferior endplate angle, vertebral body height loss, local kyphotic deformity, interspinous distance and interpedicular distance were assessed for variability. Observer values were compared with an experienced gold rater in spinal trauma. Analysis of variability was performed for all observers, between the principal investigators and also between observers participating in each center. Results: The studied parameters showed considerable variability in measurements among all observers and amongst all participating centers. The variability between the principal investigators was lower, but still substantial. The deviation of observer measurements from the gold rater were also significant for all CT parameters. Conclusions: CT-based radiological parameters previously reported to be suggestive of PLC injury showed considerable variability and magnetic resonance imaging verification of a PLC injury in all doubtful cases is suggested. … (more)
- Is Part Of:
- Global spine journal. Volume 10:Issue 2(2020)
- Journal:
- Global spine journal
- Issue:
- Volume 10:Issue 2(2020)
- Issue Display:
- Volume 10, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 10
- Issue:
- 2
- Issue Sort Value:
- 2020-0010-0002-0000
- Page Start:
- 118
- Page End:
- 129
- Publication Date:
- 2020-04
- Subjects:
- thoracolumbar fractures -- spine trauma -- posterior ligament complex -- variability -- reliability -- computed tomography
Spine -- Diseases -- Periodicals
Spine -- Diseases -- Treatment -- Periodicals
Spine -- Abnormalities -- Periodicals
Spine -- Surgery -- Periodicals
616.73 - Journal URLs:
- http://www.thieme.com/ ↗
- DOI:
- 10.1177/2192568219839414 ↗
- Languages:
- English
- ISSNs:
- 2192-5682
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12718.xml