Dosimetric comparison of TMR10 and convolution dose calculation algorithms in GammaPlan treatment planning system. Issue 1 (4th June 2019)
- Record Type:
- Journal Article
- Title:
- Dosimetric comparison of TMR10 and convolution dose calculation algorithms in GammaPlan treatment planning system. Issue 1 (4th June 2019)
- Main Title:
- Dosimetric comparison of TMR10 and convolution dose calculation algorithms in GammaPlan treatment planning system
- Authors:
- Kendall, Ethan
Algan, Ozer
Chen, Yong
Ahmad, Salahuddin - Abstract:
- Abstract: Aims: In this article, our goal is to compare the TMR10 and convolution dose calculation algorithm in GammaPlan used in stereotactic radiosurgery (SRS) treatments with Gamma Knife and to assess if the algorithms produce clinically significant differences. Materials and methods: Treatment plans were analysed from ten patients who have undergone Gamma Knife SRS treatments. Patient plans were retrospectively recalculated using Lesksell GammaPlan 10 treatment software utilising the TMR10 and convolution dose calculation algorithms in order to create a paired dataset for comparison. Evaluation was based on the dose volume histogram (parameters of minimum, mean, maximum and integral doses. Results: The ratios of average integral doses calculated by the convolution dose calculation algorithm to the average integral doses calculated by the TMR10 algorithm are 0·997 for the target ( p =0·028), 1·048 ( p =0·48) for the skull and 1·005 ( p =0·68) for the brainstem. Conclusions: Although doses calculated with the convolution algorithm resulted in slightly higher mean integral doses for the brainstem and skull critical structures when compared to that of TMR10 doses, these results were not statistically or clinically significant. Thus we continue to use the TMR10 algorithm at our clinic.
- Is Part Of:
- Journal of radiotherapy in practice. Volume 19:Issue 1(2020)
- Journal:
- Journal of radiotherapy in practice
- Issue:
- Volume 19:Issue 1(2020)
- Issue Display:
- Volume 19, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 19
- Issue:
- 1
- Issue Sort Value:
- 2020-0019-0001-0000
- Page Start:
- 93
- Page End:
- 97
- Publication Date:
- 2019-06-04
- Subjects:
- dosimetric comparison, -- Gamma knife, -- heterogeneity correction, -- stereotactic radiosurgery
Radiotherapy -- Periodicals
615.842005 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=JRP ↗
- DOI:
- 10.1017/S1460396919000347 ↗
- Languages:
- English
- ISSNs:
- 1460-3969
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 12687.xml