Dosimetric comparison between intensity-modulated radiotherapy and volumetric-modulated arc therapy in hippocampus sparing in brain metastasis treated by whole-brain irradiation and simultaneous integrated boost. Issue 1 (24th June 2019)
- Record Type:
- Journal Article
- Title:
- Dosimetric comparison between intensity-modulated radiotherapy and volumetric-modulated arc therapy in hippocampus sparing in brain metastasis treated by whole-brain irradiation and simultaneous integrated boost. Issue 1 (24th June 2019)
- Main Title:
- Dosimetric comparison between intensity-modulated radiotherapy and volumetric-modulated arc therapy in hippocampus sparing in brain metastasis treated by whole-brain irradiation and simultaneous integrated boost
- Authors:
- Saad, Ehab
Elshahat, Khaled
Metwally, Hussein - Abstract:
- Abstract: Background: While treating brain metastasis with whole-brain radiotherapy incorporating a simultaneous integrated boost (WBRT-SIB), the risk of hippocampus injury is high. The aim of this study is to compare dosimetrically between intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) in sparing of hippocampus and organs at risk (OARs) and planning target volume (PTV) coverage. Methods: In total, 16 patients presenting with more than one brain metastases were previously treated and then retrospectively planned using VMAT and IMRT techniques. For each patient, a dual-arc VMAT and another IMRT (five beams) plans were created. For both techniques, 30 Gy in 10 fractions was prescribed to the whole brain (WB) minus the hippocampi and 45 Gy in 10 fractions to the tumour with 0·5 cm margin. Dose–volume histogram (DVH), conformity index (CI) and homogeneity index (HI) of PTV, hippocampus mean and maximum dose and other OARs for both techniques were calculated and compared. Results: A statistically significant advantage was found in WB-PTV CI and HI with VMAT, compared to IMRT. There were lower hippocampus mean and maximum doses in VMAT than IMRT. The maximum hippocampus dose ranged between 15·5 and 19·2 Gy and between 18·4 and 20·6 Gy in VMAT and IMRT, respectively. The mean dose of the hippocampus ranged between 11·5 and 17·7 Gy and between 13·2 and 18·3 Gy in VMAT and IMRT, respectively. Conclusion: Using WBRT-SIB technique, VMAT showedAbstract: Background: While treating brain metastasis with whole-brain radiotherapy incorporating a simultaneous integrated boost (WBRT-SIB), the risk of hippocampus injury is high. The aim of this study is to compare dosimetrically between intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) in sparing of hippocampus and organs at risk (OARs) and planning target volume (PTV) coverage. Methods: In total, 16 patients presenting with more than one brain metastases were previously treated and then retrospectively planned using VMAT and IMRT techniques. For each patient, a dual-arc VMAT and another IMRT (five beams) plans were created. For both techniques, 30 Gy in 10 fractions was prescribed to the whole brain (WB) minus the hippocampi and 45 Gy in 10 fractions to the tumour with 0·5 cm margin. Dose–volume histogram (DVH), conformity index (CI) and homogeneity index (HI) of PTV, hippocampus mean and maximum dose and other OARs for both techniques were calculated and compared. Results: A statistically significant advantage was found in WB-PTV CI and HI with VMAT, compared to IMRT. There were lower hippocampus mean and maximum doses in VMAT than IMRT. The maximum hippocampus dose ranged between 15·5 and 19·2 Gy and between 18·4 and 20·6 Gy in VMAT and IMRT, respectively. The mean dose of the hippocampus ranged between 11·5 and 17·7 Gy and between 13·2 and 18·3 Gy in VMAT and IMRT, respectively. Conclusion: Using WBRT-SIB technique, VMAT showed better PTV coverage with less mean and maximum doses to the hippocampus than IMRT. Clinical randomised studies are needed to confirm safety and clinical benefit of WBRT-SIB. … (more)
- Is Part Of:
- Journal of radiotherapy in practice. Volume 19:Issue 1(2020)
- Journal:
- Journal of radiotherapy in practice
- Issue:
- Volume 19:Issue 1(2020)
- Issue Display:
- Volume 19, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 19
- Issue:
- 1
- Issue Sort Value:
- 2020-0019-0001-0000
- Page Start:
- 45
- Page End:
- 51
- Publication Date:
- 2019-06-24
- Subjects:
- brain metastasis, -- hippocampus sparing, -- IMRT, -- simultaneous integrated boost (SIB), -- VMAT
Radiotherapy -- Periodicals
615.842005 - Journal URLs:
- http://journals.cambridge.org/action/displayJournal?jid=JRP ↗
- DOI:
- 10.1017/S1460396919000396 ↗
- Languages:
- English
- ISSNs:
- 1460-3969
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 12687.xml