Improving biologic predictors of cycling endurance performance with near‐infrared spectroscopy derived measures of skeletal muscle respiration: E pluribus unum. Issue 2 (20th January 2020)
- Record Type:
- Journal Article
- Title:
- Improving biologic predictors of cycling endurance performance with near‐infrared spectroscopy derived measures of skeletal muscle respiration: E pluribus unum. Issue 2 (20th January 2020)
- Main Title:
- Improving biologic predictors of cycling endurance performance with near‐infrared spectroscopy derived measures of skeletal muscle respiration: E pluribus unum
- Authors:
- Batterson, Philip M.
Norton, Michael R.
Hetz, Sarah E.
Rohilla, Sachi
Lindsay, Keston G.
Subudhi, Andrew W.
Jacobs, Robert A. - Abstract:
- Abstract: The study aim was to compare the predictive validity of the often referenced traditional model of human endurance performance (i.e. oxygen consumption, VO2, or power at maximal effort, fatigue threshold values, and indices of exercise efficiency) versus measures of skeletal muscle oxidative potential in relation to endurance cycling performance. We hypothesized that skeletal muscle oxidative potential would more completely explain endurance performance than the traditional model, which has never been collectively verified with cycling. Accordingly, we obtained nine measures of VO2 or power at maximal efforts, 20 measures reflective of various fatigue threshold values, 14 indices of cycling efficiency, and near‐infrared spectroscopy‐derived measures reflecting in vivo skeletal muscle oxidative potential. Forward regression modeling identified variable combinations that best explained 25‐km time trial time‐to‐completion (TTC) across a group of trained male participants ( n = 24). The time constant for skeletal muscle oxygen consumption recovery, a validated measure of maximal skeletal muscle respiration, explained 92.7% of TTC variance by itself (Adj R 2 = .927, F = 294.2, SEE = 71.2, p < .001). Alternatively, the best complete traditional model of performance, including VO2max (L·min −1 ), %VO2max determined by the ventilatory equivalents method, and cycling economy at 50 W, only explained 76.2% of TTC variance (Adj R 2 = .762, F = 25.6, SEE = 128.7, pAbstract: The study aim was to compare the predictive validity of the often referenced traditional model of human endurance performance (i.e. oxygen consumption, VO2, or power at maximal effort, fatigue threshold values, and indices of exercise efficiency) versus measures of skeletal muscle oxidative potential in relation to endurance cycling performance. We hypothesized that skeletal muscle oxidative potential would more completely explain endurance performance than the traditional model, which has never been collectively verified with cycling. Accordingly, we obtained nine measures of VO2 or power at maximal efforts, 20 measures reflective of various fatigue threshold values, 14 indices of cycling efficiency, and near‐infrared spectroscopy‐derived measures reflecting in vivo skeletal muscle oxidative potential. Forward regression modeling identified variable combinations that best explained 25‐km time trial time‐to‐completion (TTC) across a group of trained male participants ( n = 24). The time constant for skeletal muscle oxygen consumption recovery, a validated measure of maximal skeletal muscle respiration, explained 92.7% of TTC variance by itself (Adj R 2 = .927, F = 294.2, SEE = 71.2, p < .001). Alternatively, the best complete traditional model of performance, including VO2max (L·min −1 ), %VO2max determined by the ventilatory equivalents method, and cycling economy at 50 W, only explained 76.2% of TTC variance (Adj R 2 = .762, F = 25.6, SEE = 128.7, p < .001). These results confirm our hypothesis by demonstrating that maximal rates of skeletal muscle respiration more completely explain cycling endurance performance than even the best combination of traditional variables long postulated to predict human endurance performance. Abstract : We compared the predictive validity of the often referenced traditional model of human endurance performance (i.e. oxygen consumption or power at maximal effort, fatigue threshold values, and indices of exercise efficiency) versus noninvasive near infrared spectroscopy‐derived measures of skeletal muscle oxidative potential in relation to endurance cycling performance across a group of healthy, trained participants ( n = 24). This is the first study to show that when compared to 43 traditional variables long postulated to predict human endurance performance, measures reflecting maximal rates of skeletal muscle respiration seemingly stand alone as the best. E pluribus unum; out of many, one. … (more)
- Is Part Of:
- Physiological reports. Volume 8:Issue 2(2020)
- Journal:
- Physiological reports
- Issue:
- Volume 8:Issue 2(2020)
- Issue Display:
- Volume 8, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 8
- Issue:
- 2
- Issue Sort Value:
- 2020-0008-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-01-20
- Subjects:
- exercise -- human performance -- mitochondria -- sport
Physiology -- Periodicals
571 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2051-817X ↗
http://physreports.physiology.org ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.14814/phy2.14342 ↗
- Languages:
- English
- ISSNs:
- 2051-817X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12663.xml