A "turn-on" fluorescent probe based on V-shaped bis-coumarin for detection of hydrazine. Issue 7 (14th February 2020)
- Record Type:
- Journal Article
- Title:
- A "turn-on" fluorescent probe based on V-shaped bis-coumarin for detection of hydrazine. Issue 7 (14th February 2020)
- Main Title:
- A "turn-on" fluorescent probe based on V-shaped bis-coumarin for detection of hydrazine
- Authors:
- Jiang, Xingzong
Shangguan, Mingqin
Lu, Zhen
Yi, Sili
Zeng, Xiaoyang
Zhang, Yongle
Hou, Linxi - Abstract:
- Abstract: Hydrazine (N2 H4 ) has been classified as an environmental contaminant and human carcinogen owing to its high toxicity. Exposed to high concentration of hydrazine can cause irreversible damage to human bodies. Hence, it is significant to explore an effective analytical method to selectively recognize and detect it. In this work, an intramolecular charge transfer (ICT) based probe 1 was designed and synthesized by condensation of V-shaped bis-coumarin and 4-bromobutyric acid. The V-shaped bis-coumarin with π-expanded system endowed the probe 1 larger stokes shift and superior tolerance to photobleaching. This "turn-on" probe exhibited a high selectivity towards hydrazine over other common ions and amine-containing species with a distinct fluorescent enhancement at 555 nm. It could rapidly detect hydrazine over a wide pH range and the detection limit was as low as 4.2 ppb. The large shift of absorption spectrum enabled it to detect hydrazine in real water samples and gas-state hydrazine by "naked-eyes". Graphical abstract: Image 1 Highlights: The novel V-shaped bis-coumarin with π-expanded system endowed the probe 1 larger stokes shift (95 nm) and superior tolerance to photobleaching. The large shift of absorption spectrum (103 nm) enabled it to detect hydrazine in real water samples and gas-state hydrazine by "naked-eyes". The probe 1 could detect hydrazine over a wide pH region (4-11) and low LOD value (4.2 ppb) within a short time (15 min).
- Is Part Of:
- Tetrahedron. Volume 76:Issue 7(2020)
- Journal:
- Tetrahedron
- Issue:
- Volume 76:Issue 7(2020)
- Issue Display:
- Volume 76, Issue 7 (2020)
- Year:
- 2020
- Volume:
- 76
- Issue:
- 7
- Issue Sort Value:
- 2020-0076-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-02-14
- Subjects:
- Fluorescent probe -- Bis-coumarin derivative -- Hydrazine detection -- Gaseous detection
Chemistry, Organic -- Periodicals
547.005 - Journal URLs:
- http://www.elsevier.com/journals ↗
- DOI:
- 10.1016/j.tet.2020.130921 ↗
- Languages:
- English
- ISSNs:
- 0040-4020
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8796.850000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12671.xml