Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis. (14th November 2019)
- Record Type:
- Journal Article
- Title:
- Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis. (14th November 2019)
- Main Title:
- Accuracy of a flash glucose monitoring system in dogs with diabetic ketoacidosis
- Authors:
- Malerba, Eleonora
Cattani, Chiara
Del Baldo, Francesca
Carotenuto, Gaia
Corradini, Sara
Golinelli, Stefania
Drudi, Ignazio
Fracassi, Federico - Abstract:
- Abstract: Background: A factory‐calibrated flash glucose monitoring system (FGMS; FreeStyle Libre) recently was evaluated in dogs with uncomplicated diabetes mellitus. It is not known if this system is reliable during diabetic ketoacidosis (DKA). Objectives: To assess the performance of the FGMS in dogs with DKA and to determine the effect of severity of ketosis and acidosis, lactate concentration, body condition score (BCS), and time wearing the sensor on the accuracy of the device. Animals: Fourteen client‐owned dogs with DKA. Methods: The interstitial glucose (IG) measurements were compared with blood glucose (BG) measurements obtained using a validated portable glucometer. The influence of changes in metabolic variables (β‐hydroxybutyrate, pH, bicarbonate, and lactate) and the effect of BCS and time wearing on sensor performance were evaluated. Accuracy was determined by fulfillment of ISO15197:2013 criteria. Results: Metabolic variables, BCS, and time wearing were not associated with the accuracy of the sensor. Good agreement between IG measurements and BG was obtained both before and after DKA resolution ( r = .88 and r = .93, respectively). Analytical accuracy was not achieved, whereas clinical accuracy was demonstrated with 100% and 99.6% of results in zones A + B of the Parkes consensus error grid analysis before and after DKA resolution, respectively. Conclusions and Clinical Importance: Changes in metabolic variables, BCS, and time wearing do not seem to affectAbstract: Background: A factory‐calibrated flash glucose monitoring system (FGMS; FreeStyle Libre) recently was evaluated in dogs with uncomplicated diabetes mellitus. It is not known if this system is reliable during diabetic ketoacidosis (DKA). Objectives: To assess the performance of the FGMS in dogs with DKA and to determine the effect of severity of ketosis and acidosis, lactate concentration, body condition score (BCS), and time wearing the sensor on the accuracy of the device. Animals: Fourteen client‐owned dogs with DKA. Methods: The interstitial glucose (IG) measurements were compared with blood glucose (BG) measurements obtained using a validated portable glucometer. The influence of changes in metabolic variables (β‐hydroxybutyrate, pH, bicarbonate, and lactate) and the effect of BCS and time wearing on sensor performance were evaluated. Accuracy was determined by fulfillment of ISO15197:2013 criteria. Results: Metabolic variables, BCS, and time wearing were not associated with the accuracy of the sensor. Good agreement between IG measurements and BG was obtained both before and after DKA resolution ( r = .88 and r = .93, respectively). Analytical accuracy was not achieved, whereas clinical accuracy was demonstrated with 100% and 99.6% of results in zones A + B of the Parkes consensus error grid analysis before and after DKA resolution, respectively. Conclusions and Clinical Importance: Changes in metabolic variables, BCS, and time wearing do not seem to affect agreement between IG and BG. Despite not fulfilling the ISO requirements, the FGMS provides clinically accurate estimates of BG in dogs with DKA. … (more)
- Is Part Of:
- Journal of veterinary internal medicine. Volume 34:Number 1(2020)
- Journal:
- Journal of veterinary internal medicine
- Issue:
- Volume 34:Number 1(2020)
- Issue Display:
- Volume 34, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 34
- Issue:
- 1
- Issue Sort Value:
- 2020-0034-0001-0000
- Page Start:
- 83
- Page End:
- 91
- Publication Date:
- 2019-11-14
- Subjects:
- canine -- freestyle libre -- interstitial glucose -- noninvasive glucose measurement
Veterinary medicine -- Periodicals
636.0896 - Journal URLs:
- http://www.jvetintmed.org ↗
http://www3.interscience.wiley.com/journal/118902531/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jvim.15657 ↗
- Languages:
- English
- ISSNs:
- 0891-6640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5072.365000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12664.xml