Evaluation of gap formation at the composite resin‐tooth interface after using universal adhesives: In vitro SEM study using the replica technique. Issue 2 (4th November 2019)
- Record Type:
- Journal Article
- Title:
- Evaluation of gap formation at the composite resin‐tooth interface after using universal adhesives: In vitro SEM study using the replica technique. Issue 2 (4th November 2019)
- Main Title:
- Evaluation of gap formation at the composite resin‐tooth interface after using universal adhesives: In vitro SEM study using the replica technique
- Authors:
- Kaczor‐Wiankowska, Kinga
Lipa, Sebastian
Krasowski, Michał
Sokołowski, Jerzy
Lewusz‐Butkiewicz, Katarzyna
Nowicka, Alicja - Abstract:
- Abstract: The aim of this study was to evaluate gap formation after using two universal adhesives, Peak Universal Bond (P), which contains chlorhexidine and Adhese Universal (A), which contains 10‐MDP monomer, and to compare them with two gold standard adhesives. The adhesives were tested in different etching modes, etch‐and‐rinse (ER) or self‐etch (SE), and under thermomechanical loading (TML). Two identical Class V cavities were prepared in each of 30 human third molar teeth, and resin‐composite restorations were made. Before and after TML, replicas of the restorations were prepared. Gap formation and their frequency according to the modified classification of Blunck and Zaslansky and the width of the maximum marginal gap (MG) were separately evaluated in enamel and dentin. Gap frequency did not differ significantly only in the enamel before TML, despite the use of different adhesives or etching modes. At both timepoints, the highest MG values were obtained with the Peak Universal Bond self‐etch (PSE) group in enamel (6.2 μm before TML, 12.2 μm after TML) and the Peak Universal Bond etch‐and‐rinse (PER) group in dentine (21.3 μm before TML, 35.5 μm after TML). After TML, there was a significant increase of gap frequency for Adhese universal self‐etch (ASE) group and MG values for PER, PSE, ASE groups at the resin‐enamel interface, and gap frequency and MG values for all groups at the resin‐dentin interface. Universal adhesive with 10‐MDP monomer have beneficial effect onAbstract: The aim of this study was to evaluate gap formation after using two universal adhesives, Peak Universal Bond (P), which contains chlorhexidine and Adhese Universal (A), which contains 10‐MDP monomer, and to compare them with two gold standard adhesives. The adhesives were tested in different etching modes, etch‐and‐rinse (ER) or self‐etch (SE), and under thermomechanical loading (TML). Two identical Class V cavities were prepared in each of 30 human third molar teeth, and resin‐composite restorations were made. Before and after TML, replicas of the restorations were prepared. Gap formation and their frequency according to the modified classification of Blunck and Zaslansky and the width of the maximum marginal gap (MG) were separately evaluated in enamel and dentin. Gap frequency did not differ significantly only in the enamel before TML, despite the use of different adhesives or etching modes. At both timepoints, the highest MG values were obtained with the Peak Universal Bond self‐etch (PSE) group in enamel (6.2 μm before TML, 12.2 μm after TML) and the Peak Universal Bond etch‐and‐rinse (PER) group in dentine (21.3 μm before TML, 35.5 μm after TML). After TML, there was a significant increase of gap frequency for Adhese universal self‐etch (ASE) group and MG values for PER, PSE, ASE groups at the resin‐enamel interface, and gap frequency and MG values for all groups at the resin‐dentin interface. Universal adhesive with 10‐MDP monomer have beneficial effect on the resin‐dentin interface, while chlorhexidine may reduce the resistance of the universal adhesive system to oral cavity conditions. Abstract : The type of adhesive influences gap formation and their development at the resin‐tooth interface. Scanning electron microscopy is a suitable device for evaluation of gap formation, and the replica method allows long‐term observation using the same samples. … (more)
- Is Part Of:
- Microscopy research and technique. Volume 83:Issue 2(2020)
- Journal:
- Microscopy research and technique
- Issue:
- Volume 83:Issue 2(2020)
- Issue Display:
- Volume 83, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 83
- Issue:
- 2
- Issue Sort Value:
- 2020-0083-0002-0000
- Page Start:
- 176
- Page End:
- 185
- Publication Date:
- 2019-11-04
- Subjects:
- Electron microscopy -- Technique -- Periodicals
Microscopy -- Periodicals
Microscopy -- Technique -- Periodicals
502.825 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-0029 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jemt.23400 ↗
- Languages:
- English
- ISSNs:
- 1059-910X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5760.600850
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12663.xml