Effect of train fire location on maximum smoke temperature beneath the subway tunnel ceiling. (March 2020)
- Record Type:
- Journal Article
- Title:
- Effect of train fire location on maximum smoke temperature beneath the subway tunnel ceiling. (March 2020)
- Main Title:
- Effect of train fire location on maximum smoke temperature beneath the subway tunnel ceiling
- Authors:
- Cong, Wei
Shi, Long
Shi, Zhicheng
Peng, Min
Yang, Hui
Zhang, Shaogang
Cheng, Xudong - Abstract:
- Highlights: Different train fire locations along the longitudinal centerline of the train are considered. The maximum smoke temperature beneath the tunnel ceiling for the train fire is studied. The properties of the spill plume through the train door are studied. Link the maximum smoke temperature beneath the tunnel ceiling to the spill plume through the train door. Abstract: Smoke temperature beneath tunnel ceiling is one of the most important parameters to determine its fire safety. A double long-narrow space is formed when a subway train stops inside a tunnel, where the smoke movement is quite different from those inside traditional road or train tunnel. The related smoke distributions beneath the tunnel ceiling in this double long-narrow space have been rarely investigated previously. Therefore, through this study, the effect of train fire location on the maximum smoke temperature beneath the subway tunnel ceiling were investigated both numerically and theoretically. Results showed that the smoke temperature beneath the tunnel ceiling is closely related to the spill plume through the train door, which is significantly affected by the fire location. The maximum smoke temperature beneath the tunnel ceiling increases exponentially as the fire source moves away from the train center. A modified model was then developed to predict the maximum temperatures under the spill plume considering various heat release rates and fire locations.
- Is Part Of:
- Tunnelling and underground space technology. Volume 97(2020)
- Journal:
- Tunnelling and underground space technology
- Issue:
- Volume 97(2020)
- Issue Display:
- Volume 97, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 97
- Issue:
- 2020
- Issue Sort Value:
- 2020-0097-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-03
- Subjects:
- Train fire -- Fire location -- Maximum temperature -- Subway tunnel -- FDS
Tunneling -- Periodicals
Underground construction -- Periodicals
Tunnels -- Periodicals
Underground areas -- Periodicals
624.193 - Journal URLs:
- http://www.sciencedirect.com/science/journal/08867798 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.tust.2020.103282 ↗
- Languages:
- English
- ISSNs:
- 0886-7798
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9071.405000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12648.xml