Diagnostic accuracy of 99mTc-antigranulocyte SPECT/CT in patients with osteomyelitis and orthopaedic device-related infections: A retrospective analysis. (February 2020)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of 99mTc-antigranulocyte SPECT/CT in patients with osteomyelitis and orthopaedic device-related infections: A retrospective analysis. (February 2020)
- Main Title:
- Diagnostic accuracy of 99mTc-antigranulocyte SPECT/CT in patients with osteomyelitis and orthopaedic device-related infections: A retrospective analysis
- Authors:
- Plate, A.
Weichselbaumer, V.
Schüpbach, R.
Fucentese, S.F.
Berli, M.
Hüllner, M.
Achermann, Y. - Abstract:
- Highlights: 99m Tc-antigranulocyte SPECT/CT has a high diagnostic accuracy (88.5%). It may help if standard diagnostics are not applicable or inconclusive. 99m Tc-antigranulocyte SPECT/CT is now recommended by current guidelines. Abstract: Objectives: Conventional imaging techniques are routinely used in the diagnostic work-up of patients with suspected osteomyelitis or orthopaedic implant-associated infections. Hybrid nuclear medicine imaging techniques are a suitable alternative to routine imaging modalities as they provide anatomical and functional information within one procedure. Our study investigated the performance of anti-granulocyte SPECT/CT using 99m Tc-labelled monoclonal antibodies in the diagnosis of osteomyelitis and orthopaedic implant-associated infections. Methods: In this retrospective analysis, we included patients with 99m Tc-antigranulocyte SPECT/CT acquired in the context of a suspected bone and joint infection. All patients underwent routine diagnostics and/or had a clinical follow-up of at least 12 months. Results: 26 episodes were included. Fifteen exams were performed for suspected osteomyelitis, and 11 for suspected orthopaedic implant-associated infection. SPECT/CT was ordered most often if standard diagnostic tests or conventional imaging modalities remained inconclusive. The overall sensitivity and specificity for the diagnosis of an infection were 77.8% and 94.1%, respectively. The positive predictive value was 87.5% and the negativeHighlights: 99m Tc-antigranulocyte SPECT/CT has a high diagnostic accuracy (88.5%). It may help if standard diagnostics are not applicable or inconclusive. 99m Tc-antigranulocyte SPECT/CT is now recommended by current guidelines. Abstract: Objectives: Conventional imaging techniques are routinely used in the diagnostic work-up of patients with suspected osteomyelitis or orthopaedic implant-associated infections. Hybrid nuclear medicine imaging techniques are a suitable alternative to routine imaging modalities as they provide anatomical and functional information within one procedure. Our study investigated the performance of anti-granulocyte SPECT/CT using 99m Tc-labelled monoclonal antibodies in the diagnosis of osteomyelitis and orthopaedic implant-associated infections. Methods: In this retrospective analysis, we included patients with 99m Tc-antigranulocyte SPECT/CT acquired in the context of a suspected bone and joint infection. All patients underwent routine diagnostics and/or had a clinical follow-up of at least 12 months. Results: 26 episodes were included. Fifteen exams were performed for suspected osteomyelitis, and 11 for suspected orthopaedic implant-associated infection. SPECT/CT was ordered most often if standard diagnostic tests or conventional imaging modalities remained inconclusive. The overall sensitivity and specificity for the diagnosis of an infection were 77.8% and 94.1%, respectively. The positive predictive value was 87.5% and the negative predictive value 88.9%. Diagnostic accuracy was 88.5%. Conclusions: 99m Tc-antigranulocyte SPECT/CT imaging has a high accuracy in the diagnosis of osteomyelitis and orthopaedic implant-associated infections and is a suitable non-invasive diagnostic tool if standard diagnostic examinations are inconclusive or not applicable. … (more)
- Is Part Of:
- International journal of infectious diseases. Volume 91(2020)
- Journal:
- International journal of infectious diseases
- Issue:
- Volume 91(2020)
- Issue Display:
- Volume 91, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 91
- Issue:
- 2020
- Issue Sort Value:
- 2020-0091-2020-0000
- Page Start:
- 79
- Page End:
- 86
- Publication Date:
- 2020-02
- Subjects:
- Periprosthetic joint infection (PJI) -- Osteosynthesis associated infections (OAI) -- Osteomyelitis -- 99mTc-antigranulocyte SPECT/CT -- Monoclonal antibody -- Diagnosis
Communicable diseases -- Periodicals
Communicable Diseases -- Periodicals
Communicable diseases
Periodicals
Electronic journals
616.9 - Journal URLs:
- http://bibpurl.oclc.org/web/73769 ↗
http://www.journals.elsevier.com/international-journal-of-infectious-diseases/ ↗
http://www.sciencedirect.com/science/journal/12019712 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/12019712 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/12019712 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijid.2019.11.017 ↗
- Languages:
- English
- ISSNs:
- 1201-9712
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.304750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12652.xml