Stylet slow-pull vs. standard suction technique for endoscopic ultrasound-guided fine needle biopsy in pancreatic solid lesions using 20 Gauge Procore™ needle: A multicenter randomized trial. Issue 2 (February 2020)
- Record Type:
- Journal Article
- Title:
- Stylet slow-pull vs. standard suction technique for endoscopic ultrasound-guided fine needle biopsy in pancreatic solid lesions using 20 Gauge Procore™ needle: A multicenter randomized trial. Issue 2 (February 2020)
- Main Title:
- Stylet slow-pull vs. standard suction technique for endoscopic ultrasound-guided fine needle biopsy in pancreatic solid lesions using 20 Gauge Procore™ needle: A multicenter randomized trial
- Authors:
- Di Mitri, Roberto
Mocciaro, Filippo
Antonini, Filippo
Scimeca, Daniela
Conte, Elisabetta
Bonaccorso, Ambra
Scibetta, Nunzia
Unti, Elettra
Fornelli, Adele
Giorgini, Sara
Binda, Cecilia
Macarri, Giampiero
Larghi, Alberto
Fabbri, Carlo - Abstract:
- Abstract: Background: Standard suction and slow-pull techniques have been utilized during endoscopic ultrasound-guided fine needle aspiration of pancreatic solid lesions, but the correct sampling technique remains unclear. New needles designed to obtain samples suitable for histological evaluation have become available. We performed a study comparing the two sampling methods during endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) in patients with pancreatic solid lesions. Methods: We performed EUS-FNB with a 20 Gauge FNB needle using slow-pull or standard suction techniques in a prospective, randomized, multicenter study. The primary aim was bloodiness of the collected specimens. Secondary aims were technical success and performance of the two techniques. Results: 110 patients were included (55 per group). No difference in blood contamination was observed (slow-pull 80% vs. suction 74%, p = 0.917). Technical success was 95% (96% vs. 94%, p = 0315). Sensitivity (96% vs. 93%), specificity (100% vs. 100%), positive likelihood ratio (NA), negative likelihood ratio (0.04 vs. 0.07), diagnostic accuracy (96 vs. 93%) did not differ between the two groups. Conclusion: EUS-FNB with slow-pull and standard suction techniques are comparable in terms of blood contamination providing similar high diagnostic sensitivity and accuracy in pancreatic solid lesions. The use of the new generation FNB needle allows to reach such high level of diagnostic adequacy regardless of theAbstract: Background: Standard suction and slow-pull techniques have been utilized during endoscopic ultrasound-guided fine needle aspiration of pancreatic solid lesions, but the correct sampling technique remains unclear. New needles designed to obtain samples suitable for histological evaluation have become available. We performed a study comparing the two sampling methods during endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) in patients with pancreatic solid lesions. Methods: We performed EUS-FNB with a 20 Gauge FNB needle using slow-pull or standard suction techniques in a prospective, randomized, multicenter study. The primary aim was bloodiness of the collected specimens. Secondary aims were technical success and performance of the two techniques. Results: 110 patients were included (55 per group). No difference in blood contamination was observed (slow-pull 80% vs. suction 74%, p = 0.917). Technical success was 95% (96% vs. 94%, p = 0315). Sensitivity (96% vs. 93%), specificity (100% vs. 100%), positive likelihood ratio (NA), negative likelihood ratio (0.04 vs. 0.07), diagnostic accuracy (96 vs. 93%) did not differ between the two groups. Conclusion: EUS-FNB with slow-pull and standard suction techniques are comparable in terms of blood contamination providing similar high diagnostic sensitivity and accuracy in pancreatic solid lesions. The use of the new generation FNB needle allows to reach such high level of diagnostic adequacy regardless of the technique utilized. … (more)
- Is Part Of:
- Digestive and liver disease. Volume 52:Issue 2(2020)
- Journal:
- Digestive and liver disease
- Issue:
- Volume 52:Issue 2(2020)
- Issue Display:
- Volume 52, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 52
- Issue:
- 2
- Issue Sort Value:
- 2020-0052-0002-0000
- Page Start:
- 178
- Page End:
- 184
- Publication Date:
- 2020-02
- Subjects:
- EUS-FNB -- EUS-FNA -- Stylet slow-pull technique -- Standard suction technique -- Pancreatic solid lesions
Digestive organs -- Diseases -- Periodicals
Liver -- Diseases -- Periodicals
616.33005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/15908658 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.dld.2019.08.023 ↗
- Languages:
- English
- ISSNs:
- 1590-8658
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3588.345600
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12627.xml