Gd-EOB-DTPA-enhanced MRI T1 relaxometry as an imaging-based liver function test compared with 13C-methacetin breath test. (March 2020)
- Record Type:
- Journal Article
- Title:
- Gd-EOB-DTPA-enhanced MRI T1 relaxometry as an imaging-based liver function test compared with 13C-methacetin breath test. (March 2020)
- Main Title:
- Gd-EOB-DTPA-enhanced MRI T1 relaxometry as an imaging-based liver function test compared with 13C-methacetin breath test
- Authors:
- Theilig, Dorothea
Tsereteli, Ana
Elkilany, Aboelyazid
Raabe, Philip
Lüdemann, Lutz
Malinowski, Maciej
Stockmann, Martin
Pratschke, Johann
Hamm, Bernd
Denecke, Timm
Geisel, Dominik - Abstract:
- Background: Gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) can be used as an imaging-based liver function test. This study aims to further corroborate its validity. Purpose: To compare Gd-EOB-DTPA-enhanced MRI as an imaging-based liver function test with the 13 C-methacetin breath test. Material and Methods: Fifty-three patients who underwent Gd-EOB-DTPA-enhanced MRI T1 relaxometry before and 20 min after intravenous Gd-EOB-DTPA administration as well as a 13 C-methacetin breath test (LiMAx test) were retrospectively analyzed. T1 relaxation times of liver parenchyma, total liver volume (TLV), and functional liver volume (FLV) were determined. Pearson correlations, multiple linear regression analysis, and receiver operating characteristic curve analysis were performed with indices derived from T1 relaxometry, liver volumetry, and laboratory parameters to identify the best predictor of liver function as determined by the LiMAx test. Results: T1 reduction rate (T1 RR), T1 RR × TLV, T1 RR × FLV, and T1 relaxation time 20 min after intravenous Gd-EOB administration showed a statistically significant correlation with LiMAx and discriminatory capacity between patients with LiMAx of > and < 315 µg/kg/h. Of the indices investigated, T1 RR showed the best discriminatory capacity and proved to be the only statistically significant parameter in multiple linear regression analysis. Conclusion: Gd-EOB-DTPA-enhanced MRI asBackground: Gadolinium ethoxybenzyl diethylenetriaminepentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) can be used as an imaging-based liver function test. This study aims to further corroborate its validity. Purpose: To compare Gd-EOB-DTPA-enhanced MRI as an imaging-based liver function test with the 13 C-methacetin breath test. Material and Methods: Fifty-three patients who underwent Gd-EOB-DTPA-enhanced MRI T1 relaxometry before and 20 min after intravenous Gd-EOB-DTPA administration as well as a 13 C-methacetin breath test (LiMAx test) were retrospectively analyzed. T1 relaxation times of liver parenchyma, total liver volume (TLV), and functional liver volume (FLV) were determined. Pearson correlations, multiple linear regression analysis, and receiver operating characteristic curve analysis were performed with indices derived from T1 relaxometry, liver volumetry, and laboratory parameters to identify the best predictor of liver function as determined by the LiMAx test. Results: T1 reduction rate (T1 RR), T1 RR × TLV, T1 RR × FLV, and T1 relaxation time 20 min after intravenous Gd-EOB administration showed a statistically significant correlation with LiMAx and discriminatory capacity between patients with LiMAx of > and < 315 µg/kg/h. Of the indices investigated, T1 RR showed the best discriminatory capacity and proved to be the only statistically significant parameter in multiple linear regression analysis. Conclusion: Gd-EOB-DTPA-enhanced MRI as an imaging-based liver function test also correlates with the LiMAx test which in turn reflects cytochrome P450 function. The T1 reduction rate of the liver on Gd-EOB-DTPA-enhanced MRI allows prediction of liver function as determined by the LiMAx test both for 1.5 and 3.0 T. … (more)
- Is Part Of:
- Acta radiologica. Volume 61:Number 3(2020)
- Journal:
- Acta radiologica
- Issue:
- Volume 61:Number 3(2020)
- Issue Display:
- Volume 61, Issue 3 (2020)
- Year:
- 2020
- Volume:
- 61
- Issue:
- 3
- Issue Sort Value:
- 2020-0061-0003-0000
- Page Start:
- 291
- Page End:
- 301
- Publication Date:
- 2020-03
- Subjects:
- Liver -- magnetic resonance imaging -- contrast agent
Radiology, Medical -- Periodicals
Radiography, Medical -- Periodicals
Radiotherapy -- Periodicals
616.0757 - Journal URLs:
- http://acr.sagepub.com ↗
http://ar.rsmjournals.com ↗
http://www.uk.sagepub.com/home.nav ↗
http://informahealthcare.com/loi/ard ↗
http://www.tandf.co.uk/journals/titles/02841851.asp ↗ - DOI:
- 10.1177/0284185119861314 ↗
- Languages:
- English
- ISSNs:
- 0284-1851
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0662.000000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12624.xml