Numerical study of isolation in the backfill zone of foundation pit method to reduce railway generated vibration in high‐rise buildings. (18th November 2019)
- Record Type:
- Journal Article
- Title:
- Numerical study of isolation in the backfill zone of foundation pit method to reduce railway generated vibration in high‐rise buildings. (18th November 2019)
- Main Title:
- Numerical study of isolation in the backfill zone of foundation pit method to reduce railway generated vibration in high‐rise buildings
- Authors:
- Pan, Peng
Zeng, Yi
Yang, Jun
Zhang, Dongbin - Abstract:
- Summary: The conventional methods to reduce building vibration include isolation of vibration sources, isolation of buildings, and setting trenches in the propagation path. However, it is evidenced that these methods are not feasible for high‐rise buildings in crowded urban areas. This paper proposes a new method to reduce vibration for high‐rise buildings by using the existing construction backfill zone, the isolation in the backfill zone of foundation pit (IBF). Numerical analyses were first carried out to obtain a realistic excitation time history, and a finite element–infinite element model was developed and calibrated using test data from an actual building site. The contributions of the basement sidewalls and foundation slabs to floor vibration and the influence of infill material properties are investigated. Lastly, a composite isolation layer was suggested to provide both sufficient restraining effects to the building foundation and satisfactory vibration isolation. The analyses confirmed that the proposed IBF method reduces ground‐borne vibration in high‐rise buildings by up to 66% when railway is on the ground.
- Is Part Of:
- Structural design of tall and special buildings. Volume 29:Number 2(2020)
- Journal:
- Structural design of tall and special buildings
- Issue:
- Volume 29:Number 2(2020)
- Issue Display:
- Volume 29, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 29
- Issue:
- 2
- Issue Sort Value:
- 2020-0029-0002-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2019-11-18
- Subjects:
- backfill zone of foundation pit -- composite isolation layer -- finite element–infinite element -- high‐rise building -- inverse procedure -- railway generated vibration reduction
Tall buildings -- Design and construction -- Periodicals
Structural design -- Periodicals
690.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/tal.1691 ↗
- Languages:
- English
- ISSNs:
- 1541-7794
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8476.927000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12616.xml