Safety and reliability of a handheld stimulator for neural monitoring during thyroid surgery. (25th April 2019)
- Record Type:
- Journal Article
- Title:
- Safety and reliability of a handheld stimulator for neural monitoring during thyroid surgery. (25th April 2019)
- Main Title:
- Safety and reliability of a handheld stimulator for neural monitoring during thyroid surgery
- Authors:
- Lawson, Bradley R.
Kamani, Dipti
Shama, Mohamed
Kyriazidis, Natalia
Randolph, Gregory W. - Abstract:
- Abstract : Objective: The Checkpoint nerve stimulator (Checkpoint Surgical, Cleveland, OH) is a U.S. Food and Drug Administration‐approved device for neural localization and monitoring during surgery. Its safety, efficacy, and reliability for neural monitoring during thyroid and parathyroid surgery have not been compared to more standard formats of neural monitoring. Study Design: Retrospective review. Methods: Vagal, recurrent, and superior laryngeal nerve monitoring were performed using both the Checkpoint stimulator and Medtronic NIM 3.0 laryngeal electromyography endotracheal tube (Medtronic, Jacksonville, FL) during thyroid and parathyroid surgery. A total of 21 operated sides in 15 patients were included for analysis. Latency and amplitude data for the Checkpoint stimulator were recorded using the NIM monitor and compared to normative endotracheal tube surface electrode data. Results: Mean amplitude using the Checkpoint stimulator was 574.6 microvolts (μV), 1060.6 μV, and 182.8 μV for the vagus, recurrent laryngeal, and superior laryngeal nerves, respectively. Mean amplitude using standard laryngeal electromyography was 709 μV, 1077.0 μV, and 183.7 μV for the same nerves. Mean latency was significantly shorter with stimulation of the recurrent laryngeal nerve compared to the vagus nerve with both stimulators ( P < 0.001). No neural injuries occurred during the study. Conclusion: The Checkpoint stimulator is a safe and reliable alternative to traditional laryngealAbstract : Objective: The Checkpoint nerve stimulator (Checkpoint Surgical, Cleveland, OH) is a U.S. Food and Drug Administration‐approved device for neural localization and monitoring during surgery. Its safety, efficacy, and reliability for neural monitoring during thyroid and parathyroid surgery have not been compared to more standard formats of neural monitoring. Study Design: Retrospective review. Methods: Vagal, recurrent, and superior laryngeal nerve monitoring were performed using both the Checkpoint stimulator and Medtronic NIM 3.0 laryngeal electromyography endotracheal tube (Medtronic, Jacksonville, FL) during thyroid and parathyroid surgery. A total of 21 operated sides in 15 patients were included for analysis. Latency and amplitude data for the Checkpoint stimulator were recorded using the NIM monitor and compared to normative endotracheal tube surface electrode data. Results: Mean amplitude using the Checkpoint stimulator was 574.6 microvolts (μV), 1060.6 μV, and 182.8 μV for the vagus, recurrent laryngeal, and superior laryngeal nerves, respectively. Mean amplitude using standard laryngeal electromyography was 709 μV, 1077.0 μV, and 183.7 μV for the same nerves. Mean latency was significantly shorter with stimulation of the recurrent laryngeal nerve compared to the vagus nerve with both stimulators ( P < 0.001). No neural injuries occurred during the study. Conclusion: The Checkpoint stimulator is a safe and reliable alternative to traditional laryngeal electromyography providing equivalent induced electromyography of the vocalis for neural monitoring during thyroid and parathyroid surgery. Level of Evidence: 4 Laryngoscope, 130:561–565, 2020 … (more)
- Is Part Of:
- Laryngoscope. Volume 130:Number 2(2020)
- Journal:
- Laryngoscope
- Issue:
- Volume 130:Number 2(2020)
- Issue Display:
- Volume 130, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 130
- Issue:
- 2
- Issue Sort Value:
- 2020-0130-0002-0000
- Page Start:
- 561
- Page End:
- 565
- Publication Date:
- 2019-04-25
- Subjects:
- Endotracheal tube surface electrodes -- Checkpoint stimulator -- neural monitoring -- nerve stimulator -- electromyography -- thyroid surgery -- parathyroid surgery
Otolaryngology -- Periodicals
617.51005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1531-4995/issues ↗
http://www.interscience.wiley.com/jpages/0023-852X ↗
http://www.laryngoscope.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/lary.28027 ↗
- Languages:
- English
- ISSNs:
- 0023-852X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5156.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12612.xml