Comparison of 2‐Dimensional Shear Wave Elastographic Measurements Using ElastQ Imaging and SuperSonic Shear Imaging: Phantom Study and Clinical Pilot Study. (8th August 2019)
- Record Type:
- Journal Article
- Title:
- Comparison of 2‐Dimensional Shear Wave Elastographic Measurements Using ElastQ Imaging and SuperSonic Shear Imaging: Phantom Study and Clinical Pilot Study. (8th August 2019)
- Main Title:
- Comparison of 2‐Dimensional Shear Wave Elastographic Measurements Using ElastQ Imaging and SuperSonic Shear Imaging: Phantom Study and Clinical Pilot Study
- Authors:
- Hwang, Jisun
Yoon, Hee Mang
Jung, Ah Young
Lee, Jin Seong
Cho, Young Ah - Abstract:
- Abstract : Objectives: To compare the feasibility and clinical applicability of ElastQ imaging (Philips Healthcare, Best, the Netherlands) with that of SuperSonic shear imaging (SSI; SuperSonic Imagine, Aix‐en‐Provence, France) using an elastographic phantom and a pilot study of patients. Methods: Two‐dimensional shear wave elastography measurement was performed by ElastQ imaging and SSI by 2 radiologists. An elastographic phantom with 5 target elasticities at 2 acquisition depths was used. The coefficients of variation and intraclass correlation coefficients (ICCs) were evaluated for repeatability and interobserver agreement, respectively. The mean elasticities of the systems at each target were compared. The proportions of measurements that were out of the range of expected values and measurement errors were calculated to determine accuracy. Liver stiffness (LS) was measured by both systems in 27 children and young adult patients with various liver diseases. Results: Both systems provided high repeatability in elasticity measurements of phantom targets (coefficients of variation, 0.69%–15.82%), and there was excellent interobserver agreement (ICC, 0.992). Most (90%) mean elasticities of targets were significantly different between the techniques ( P ≤ .002) and acquisition depths ( P ≤ .004). ElastQ imaging had significantly lower proportions of out‐of‐range measurements and measurement errors ( P ≤ .003) than SSI. In patients with liver disease, LS measurements of theAbstract : Objectives: To compare the feasibility and clinical applicability of ElastQ imaging (Philips Healthcare, Best, the Netherlands) with that of SuperSonic shear imaging (SSI; SuperSonic Imagine, Aix‐en‐Provence, France) using an elastographic phantom and a pilot study of patients. Methods: Two‐dimensional shear wave elastography measurement was performed by ElastQ imaging and SSI by 2 radiologists. An elastographic phantom with 5 target elasticities at 2 acquisition depths was used. The coefficients of variation and intraclass correlation coefficients (ICCs) were evaluated for repeatability and interobserver agreement, respectively. The mean elasticities of the systems at each target were compared. The proportions of measurements that were out of the range of expected values and measurement errors were calculated to determine accuracy. Liver stiffness (LS) was measured by both systems in 27 children and young adult patients with various liver diseases. Results: Both systems provided high repeatability in elasticity measurements of phantom targets (coefficients of variation, 0.69%–15.82%), and there was excellent interobserver agreement (ICC, 0.992). Most (90%) mean elasticities of targets were significantly different between the techniques ( P ≤ .002) and acquisition depths ( P ≤ .004). ElastQ imaging had significantly lower proportions of out‐of‐range measurements and measurement errors ( P ≤ .003) than SSI. In patients with liver disease, LS measurements of the systems were strongly correlated (ρ = 0.955; P < .001) and had excellent agreement (ICC, 0.951; P < .001). Conclusions: ElastQ imaging had comparably good results in terms of repeatability, interobserver agreement, and accuracy in the phantom model compared with SSI. The pilot patient study showed strong correlations in LS values between the systems. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 39:Number 2(2020)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 39:Number 2(2020)
- Issue Display:
- Volume 39, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 39
- Issue:
- 2
- Issue Sort Value:
- 2020-0039-0002-0000
- Page Start:
- 311
- Page End:
- 321
- Publication Date:
- 2019-08-08
- Subjects:
- liver -- phantom study -- shear wave elastography -- ultrasound
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jum.15108 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12608.xml