Garg, Anurag - Abstract:
- Summary: A 24‐year‐old male was scheduled for excision of a cerebellopontine angle tumour. The left internal jugular vein was cannulated preoperatively. The post procedure chest X‐ray showed the tip of the cannula in the left upper zone of the lung; however, blood could be freely aspirated and the transducer trace indicated a mean pressure of 5 mmHg. Blood gas analysis revealed a PaO2 of 13.6 kPa. Angiography confirmed the patients had partial anomalous pulmonary venous drainage with the tip of the catheter situated in the left upper pulmonary vein.
- Is Part Of:
- Anaesthesia cases. Volume 3:Issue 1(2015)
- Journal:
- Anaesthesia cases
- Issue:
- Volume 3:Issue 1(2015)
- Issue Display:
- Volume 3, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 3
- Issue:
- 1
- Issue Sort Value:
- 2015-0003-0001-0000
- Page Start:
- 61
- Page End:
- 63
- Publication Date:
- 2015-05-21
- Subjects:
- 617.9605
- Journal URLs:
- http://www.anaesthesiacases.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.21466/ac.AMCLABG.2015 ↗
- Languages:
- English
- ISSNs:
- 2396-8397
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12598.xml