Early Clinical Experiences of Robotic Assisted Aortic Valve Replacement for Aortic Valve Stenosis with Sutureless Aortic Valve. Issue 1 (February 2020)
- Record Type:
- Journal Article
- Title:
- Early Clinical Experiences of Robotic Assisted Aortic Valve Replacement for Aortic Valve Stenosis with Sutureless Aortic Valve. Issue 1 (February 2020)
- Main Title:
- Early Clinical Experiences of Robotic Assisted Aortic Valve Replacement for Aortic Valve Stenosis with Sutureless Aortic Valve
- Authors:
- Nagaoka, Eiki
Gelinas, Jill
Vola, Marco
Kiaii, Bob - Abstract:
- Robotic assisted aortic valve surgery is still challenging and debatable. We retrospectively reviewed our cases of robotic assisted aortic valve replacement utilizing sutureless aortic valve with following surgical technique: 3 ports, 1 for endoscope and 2 for the robotic arms were inserted in the right chest and da Vinci Si robotic system (Intuitive Surgical, Sunnyvale, CA, USA) was adapted to these ports. Cardiopulmonary bypass was initiated through peripheral cannulations. A vent cannula was placed through the right superior pulmonary vein and a cardioplegia cannula in the ascending aorta. After cardioplegic arrest following aortic cross-clamp, the aortic valve was exposed through a clam shell aortotomy. Valvectomy along with decalcification was performed. Next using 3 guiding sutures the Perceval S valve (LivaNova, London, UK) was parachuted down and deployed. After confirming valve position, the aortotomy was closed. There were no major complications during the procedures and no conversion to sternotomy. Exposure of aortic valve was of high quality. Valvectomy required assistance with long scissors by the bedside surgeon for excision of the severely calcified valve cusps and effective decalcification of annulus. Postoperative convalescence was uncomplicated except for postoperative atrial fibrillation in 1 patient. Robotic assistance in aortic valve procedure enabled excellent exposure of the aortic valve and improved manipulation and suturing of the aortic annulus andRobotic assisted aortic valve surgery is still challenging and debatable. We retrospectively reviewed our cases of robotic assisted aortic valve replacement utilizing sutureless aortic valve with following surgical technique: 3 ports, 1 for endoscope and 2 for the robotic arms were inserted in the right chest and da Vinci Si robotic system (Intuitive Surgical, Sunnyvale, CA, USA) was adapted to these ports. Cardiopulmonary bypass was initiated through peripheral cannulations. A vent cannula was placed through the right superior pulmonary vein and a cardioplegia cannula in the ascending aorta. After cardioplegic arrest following aortic cross-clamp, the aortic valve was exposed through a clam shell aortotomy. Valvectomy along with decalcification was performed. Next using 3 guiding sutures the Perceval S valve (LivaNova, London, UK) was parachuted down and deployed. After confirming valve position, the aortotomy was closed. There were no major complications during the procedures and no conversion to sternotomy. Exposure of aortic valve was of high quality. Valvectomy required assistance with long scissors by the bedside surgeon for excision of the severely calcified valve cusps and effective decalcification of annulus. Postoperative convalescence was uncomplicated except for postoperative atrial fibrillation in 1 patient. Robotic assistance in aortic valve procedure enabled excellent exposure of the aortic valve and improved manipulation and suturing of the aortic annulus and aorta. There needs to be improvement of instrumentation for valve debridement and removal of calcium from the annulus. In addition, the sutureless valve technology contributes to the feasibility and the efficacy of this procedure. … (more)
- Is Part Of:
- Innovations. Volume 15:Issue 1(2020)
- Journal:
- Innovations
- Issue:
- Volume 15:Issue 1(2020)
- Issue Display:
- Volume 15, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 15
- Issue:
- 1
- Issue Sort Value:
- 2020-0015-0001-0000
- Page Start:
- 88
- Page End:
- 92
- Publication Date:
- 2020-02
- Subjects:
- robotic surgery -- minimally invasive aortic valve replacement -- sutureless aortic valve
Cardiovascular system -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
Blood-vessels -- Surgery -- Periodicals
Chest -- Surgery -- Periodicals
Thoracic Surgical Procedures -- methods -- Periodicals
Vascular Surgical Procedures -- methods -- Periodicals
Thorax -- Chirurgie -- Méthodologie -- Périodiques
Vaisseaux sanguins -- Chirurgie -- Méthodologie -- Périodiques
Blood-vessels -- Surgery
Chest -- Surgery
Periodicals
617.41 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01243895-000000000-00000 ↗
http://journals.lww.com/innovjournal/pages/default.aspx ↗
http://www.lww.com/product/?1556-9845 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1177/1556984519894298 ↗
- Languages:
- English
- ISSNs:
- 1556-9845
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12594.xml