Comparison of T2*GRE and DSC-PWI for hemorrhage detection in acute ischemic stroke patients: Pooled analysis of the EPITHET, DEFUSE 2, and SENSE 3 stroke studies. Issue 2 (February 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of T2*GRE and DSC-PWI for hemorrhage detection in acute ischemic stroke patients: Pooled analysis of the EPITHET, DEFUSE 2, and SENSE 3 stroke studies. Issue 2 (February 2020)
- Main Title:
- Comparison of T2*GRE and DSC-PWI for hemorrhage detection in acute ischemic stroke patients: Pooled analysis of the EPITHET, DEFUSE 2, and SENSE 3 stroke studies
- Authors:
- Amukotuwa, Shalini A
Fischbein, Nancy J
Albers, Gregory W
Davis, Stephen
Donnan, Geoffrey A
Andre, Jalal B
Bammer, Roland - Abstract:
- Aims: The objective of this study was to compare the diagnostic performance of the baseline pre-contrast images of dynamic susceptibility contrast perfusion-weighted imaging (DSC-PWI) with conventional T2*gradient recalled echo (GRE) imaging for detection of hemorrhage in acute ischemic stroke patients. Material and methods: T2*GRE and DSC-PWI from 393 magnetic resonance imaging scans from 221 patients enrolled in three prospective stroke studies were independently evaluated by two readers blinded to clinical and other imaging data. Agreement between T2*GRE and DSC-PWI for the presence of hemorrhage, and acute hemorrhagic transformation, was assessed using the kappa statistic. Inter-reader agreement was also assessed using the kappa statistic. Results: Agreement between the baseline images of DSC-PWI and T2*GRE regarding the presence of hemorrhage was almost perfect (kreader 1 : 0.90, 95% confidence interval 0.86–0.95 and kreader 2 : 0.91, 95% confidence interval 0.87–0.96). Agreement between the sequences was still higher for detection of acute hemorrhagic transformation (kreader 1 : 0.94, 95% confidence interval 0.91–0.98 and kreader 2 : 0.95, 95% confidence interval 0.92–0.98). Inter-reader agreement for detection of hemorrhage was also almost perfect for both T2*GRE (k: 0.95, 95% confidence interval 0.91–0.98) and DSC-PWI (k: 0.96, 95% confidence interval 0.93–0.99). Acute hemorrhagic transformation detected on T2*GRE was missed on DSC-PWI by one or both readers inAims: The objective of this study was to compare the diagnostic performance of the baseline pre-contrast images of dynamic susceptibility contrast perfusion-weighted imaging (DSC-PWI) with conventional T2*gradient recalled echo (GRE) imaging for detection of hemorrhage in acute ischemic stroke patients. Material and methods: T2*GRE and DSC-PWI from 393 magnetic resonance imaging scans from 221 patients enrolled in three prospective stroke studies were independently evaluated by two readers blinded to clinical and other imaging data. Agreement between T2*GRE and DSC-PWI for the presence of hemorrhage, and acute hemorrhagic transformation, was assessed using the kappa statistic. Inter-reader agreement was also assessed using the kappa statistic. Results: Agreement between the baseline images of DSC-PWI and T2*GRE regarding the presence of hemorrhage was almost perfect (kreader 1 : 0.90, 95% confidence interval 0.86–0.95 and kreader 2 : 0.91, 95% confidence interval 0.87–0.96). Agreement between the sequences was still higher for detection of acute hemorrhagic transformation (kreader 1 : 0.94, 95% confidence interval 0.91–0.98 and kreader 2 : 0.95, 95% confidence interval 0.92–0.98). Inter-reader agreement for detection of hemorrhage was also almost perfect for both T2*GRE (k: 0.95, 95% confidence interval 0.91–0.98) and DSC-PWI (k: 0.96, 95% confidence interval 0.93–0.99). Acute hemorrhagic transformation detected on T2*GRE was missed on DSC-PWI by one or both readers in 5/393 (1.3%) scans. Conclusion: The almost perfect statistical agreement between DSC-PWI and conventional T2*GRE suggests that DSC-PWI is sufficient for hemorrhage screening prior to thrombolysis in stroke patients. T2*GRE can therefore be omitted when DSC-PWI is included, thereby shortening the acute ischemic stroke magnetic resonance imaging protocol and expediting treatment. Trial registration: ClinicalTrials.gov Identifier: NCT02586415. … (more)
- Is Part Of:
- International journal of stroke. Volume 15:Issue 2(2020)
- Journal:
- International journal of stroke
- Issue:
- Volume 15:Issue 2(2020)
- Issue Display:
- Volume 15, Issue 2 (2020)
- Year:
- 2020
- Volume:
- 15
- Issue:
- 2
- Issue Sort Value:
- 2020-0015-0002-0000
- Page Start:
- 216
- Page End:
- 225
- Publication Date:
- 2020-02
- Subjects:
- Brain bleed -- brain microbleeds -- cerebral hemorrhage -- cerebral infarction -- magnetic resonance imaging -- stroke
616.8005 - Journal URLs:
- http://wso.sagepub.com/ ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=ijs ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1177/1747493019858781 ↗
- Languages:
- English
- ISSNs:
- 1747-4930
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.681485
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12588.xml