Controlled Release of Vancomycin and Tigecycline from an Orthopaedic Implant Coating Prevents Staphylococcus aureus Infection in an Open Fracture Animal Model. (12th December 2019)
- Record Type:
- Journal Article
- Title:
- Controlled Release of Vancomycin and Tigecycline from an Orthopaedic Implant Coating Prevents Staphylococcus aureus Infection in an Open Fracture Animal Model. (12th December 2019)
- Main Title:
- Controlled Release of Vancomycin and Tigecycline from an Orthopaedic Implant Coating Prevents Staphylococcus aureus Infection in an Open Fracture Animal Model
- Authors:
- Stavrakis, A. I.
Zhu, S.
Loftin, A. H.
Weixian, X.
Niska, J.
Hegde, V.
Segura, T.
Bernthal, N. M. - Other Names:
- Grassi Alberto Academic Editor.
- Abstract:
- Abstract : Introduction . Treatment of open fractures routinely involves multiple surgeries and delayed definitive fracture fixation because of concern for infection. If implants were made less susceptible to infection, a one-stage procedure with intramedullary nailing would be more feasible, which would reduce morbidity and improve outcomes. Methods . In this study, a novel open fracture mouse model was developed using Staphylococcus aureus ( S. aureus ) and single-stage intramedullary fixation. The model was used to evaluate whether implants coated with a novel "smart" polymer coating containing vancomycin or tigecycline would be colonized by bacteria in an open fracture model infected with S. aureus . In vivo bioluminescence, ex vivo CFUs, and X-ray images were evaluated over a 42-day postoperative period. Results . We found evidence of a markedly decreased bacterial burden with the local release of vancomycin and tigecycline from the PEG-PPS polymer compared to polymer alone. Vancomycin was released in a controlled fashion and maintained local drug concentrations above the minimum inhibition concentration for S. aureus for greater than 7 days postoperatively. Bacteria were reduced 139-fold from implants containing vancomycin and undetected from the bone and soft tissue. Tigecycline coatings led to a 5991-fold reduction in bacteria isolated from bone and soft tissue and 15-fold reduction on the implants compared to polymer alone. Antibiotic coatings also preventedAbstract : Introduction . Treatment of open fractures routinely involves multiple surgeries and delayed definitive fracture fixation because of concern for infection. If implants were made less susceptible to infection, a one-stage procedure with intramedullary nailing would be more feasible, which would reduce morbidity and improve outcomes. Methods . In this study, a novel open fracture mouse model was developed using Staphylococcus aureus ( S. aureus ) and single-stage intramedullary fixation. The model was used to evaluate whether implants coated with a novel "smart" polymer coating containing vancomycin or tigecycline would be colonized by bacteria in an open fracture model infected with S. aureus . In vivo bioluminescence, ex vivo CFUs, and X-ray images were evaluated over a 42-day postoperative period. Results . We found evidence of a markedly decreased bacterial burden with the local release of vancomycin and tigecycline from the PEG-PPS polymer compared to polymer alone. Vancomycin was released in a controlled fashion and maintained local drug concentrations above the minimum inhibition concentration for S. aureus for greater than 7 days postoperatively. Bacteria were reduced 139-fold from implants containing vancomycin and undetected from the bone and soft tissue. Tigecycline coatings led to a 5991-fold reduction in bacteria isolated from bone and soft tissue and 15-fold reduction on the implants compared to polymer alone. Antibiotic coatings also prevented osteomyelitis and implant loosening as observed on X-ray. Conclusion . Vancomycin and tigecycline can be encapsulated in a polymer coating and released over time to maintain therapeutic levels during the perioperative period. Our results suggest that antibiotic coatings can be used to prevent implant infection and osteomyelitis in the setting of open fracture. This novel open fracture mouse model can be used as a powerful in vivo preclinical tool to evaluate and optimize the treatment of open fractures before further studies in humans. … (more)
- Is Part Of:
- BioMed research international. Volume 2019(2019)
- Journal:
- BioMed research international
- Issue:
- Volume 2019(2019)
- Issue Display:
- Volume 2019, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 2019
- Issue:
- 2019
- Issue Sort Value:
- 2019-2019-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-12-12
- Subjects:
- Medicine -- Periodicals
Biology -- Periodicals
Biotechnology -- Periodicals
Life sciences -- Periodicals
610.5 - Journal URLs:
- https://www.hindawi.com/journals/bmri/ ↗
- DOI:
- 10.1155/2019/1638508 ↗
- Languages:
- English
- ISSNs:
- 2314-6133
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 12573.xml