Algorithm-based artifact reduction in patients with arms-down positioning in computed tomography. (January 2020)
- Record Type:
- Journal Article
- Title:
- Algorithm-based artifact reduction in patients with arms-down positioning in computed tomography. (January 2020)
- Main Title:
- Algorithm-based artifact reduction in patients with arms-down positioning in computed tomography
- Authors:
- Kawashima, Hiroki
Ichikawa, Katsuhiro
Takata, Tadanori
Mitsui, Wataru - Abstract:
- Highlights: Arm-artifacts are observed in computed tomography with arms-down positioning. An algorithm of selective arm-induced noise filtering is proposed in this study. The artifact reduction performance was compared with hybrid IR and MBIR. The proposed algorithm significantly reduced the arm-artifacts similarly to MBIR. The spatial resolution preservation performance was superior to MBIR. Abstract: Purpose: Arm-artifact, a type of streak artifact frequently observed in computed tomography (CT) images obtained at arms-down positioning in polytrauma patients, is known to degrade image quality. This study aimed to develop a novel arm-artifact reduction algorithm (AAR) applied to projection data. Methods: A phantom resembling an adult abdomen with two arms was scanned using a 16-row CT scanner. The projection data were processed by AAR, and CT images were reconstructed. The artifact reduction for the same phantom was compared with that achieved by two latest iterative reconstruction (IR) techniques (IR1 and IR2) using a normalized artifact index (nAI) at two locations (ventral and dorsal side). Image blurring as a processing side effect was compared with IR2 of the model-based IR using a plastic needle phantom. Additionally, the projection data of two clinical cases were processed using AAR, and the image noise was evaluated. Results: AAR and IR2 significantly reduced nAI by 87.5% and 74.0%, respectively at the ventral side and 84.2% and 69.6%, respectively, at the dorsalHighlights: Arm-artifacts are observed in computed tomography with arms-down positioning. An algorithm of selective arm-induced noise filtering is proposed in this study. The artifact reduction performance was compared with hybrid IR and MBIR. The proposed algorithm significantly reduced the arm-artifacts similarly to MBIR. The spatial resolution preservation performance was superior to MBIR. Abstract: Purpose: Arm-artifact, a type of streak artifact frequently observed in computed tomography (CT) images obtained at arms-down positioning in polytrauma patients, is known to degrade image quality. This study aimed to develop a novel arm-artifact reduction algorithm (AAR) applied to projection data. Methods: A phantom resembling an adult abdomen with two arms was scanned using a 16-row CT scanner. The projection data were processed by AAR, and CT images were reconstructed. The artifact reduction for the same phantom was compared with that achieved by two latest iterative reconstruction (IR) techniques (IR1 and IR2) using a normalized artifact index (nAI) at two locations (ventral and dorsal side). Image blurring as a processing side effect was compared with IR2 of the model-based IR using a plastic needle phantom. Additionally, the projection data of two clinical cases were processed using AAR, and the image noise was evaluated. Results: AAR and IR2 significantly reduced nAI by 87.5% and 74.0%, respectively at the ventral side and 84.2% and 69.6%, respectively, at the dorsal side compared with each filtered back projection ( P < 0.01), whereas IR1 did not. The proposed algorithm mostly maintained the original spatial resolution, compared with IR2, which yielded apparent image blurring. The image noise in the clinical cases was also reduced significantly ( P < 0.01). Conclusions: AAR was more effective and superior than the latest IR techniques and is expected to improve the image quality of polytrauma CT imaging with arms-down positioning. … (more)
- Is Part Of:
- Physica medica. Volume 69(2020)
- Journal:
- Physica medica
- Issue:
- Volume 69(2020)
- Issue Display:
- Volume 69, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 69
- Issue:
- 2020
- Issue Sort Value:
- 2020-0069-2020-0000
- Page Start:
- 61
- Page End:
- 69
- Publication Date:
- 2020-01
- Subjects:
- Computed tomography -- Artifact -- Polytrauma -- Image quality -- Reconstruction algorithm
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.11.019 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12565.xml