Microdosimetric modeling of the sensitometric curve of GafChromic films in the photon fields. (January 2020)
- Record Type:
- Journal Article
- Title:
- Microdosimetric modeling of the sensitometric curve of GafChromic films in the photon fields. (January 2020)
- Main Title:
- Microdosimetric modeling of the sensitometric curve of GafChromic films in the photon fields
- Authors:
- Moslehi, A.
Ansari, M.
Monadi, Sh. - Abstract:
- Highlights: Calibration curve of EBT3 GafChromic film is experimentally measured. The calibration curve is calculated by the microdosimetric one-hit detector model. The saturation parameters are determined by the single-event microdosimetric spectra. The calculated calibration curve is 11% different from the measurements in the worst case. Abstract: The sensitometric curve of EBT3 GafChromic film located at a depth 5 cm of RW3 water-equivalent phantom exposed to 6 MV X-rays is investigated. Variation of optical density for absorbed doses less than 2 Gy is determined by the experimental measurement together with the microdosimetric one-hit detector model. It is found that this model needs two fitting parameters, a maximum optical density and a saturation parameter. Both of them depend on the film structure as well as the photon spectrum. Meanwhile, the saturation parameter is a function of the microdosimetric single-event distribution of specific energy, i.e., f 1 ( z ) . To calculate this distribution, irradiation of the films is simulated by the Geant4 toolkit. A sample of EBT3 film with 2 mm × 2 mm area is simulated. Active layer of the film is considered to contain 5000 cylindrical sensitive targets (SV) with 9.4 μ m length and 1.62 μ m diameter, located in random positions with different axial directions. The results obtained show that below an absorbed dose 1 Gy the maximum difference between the measured and the calculated optical densities is about 11%, while forHighlights: Calibration curve of EBT3 GafChromic film is experimentally measured. The calibration curve is calculated by the microdosimetric one-hit detector model. The saturation parameters are determined by the single-event microdosimetric spectra. The calculated calibration curve is 11% different from the measurements in the worst case. Abstract: The sensitometric curve of EBT3 GafChromic film located at a depth 5 cm of RW3 water-equivalent phantom exposed to 6 MV X-rays is investigated. Variation of optical density for absorbed doses less than 2 Gy is determined by the experimental measurement together with the microdosimetric one-hit detector model. It is found that this model needs two fitting parameters, a maximum optical density and a saturation parameter. Both of them depend on the film structure as well as the photon spectrum. Meanwhile, the saturation parameter is a function of the microdosimetric single-event distribution of specific energy, i.e., f 1 ( z ) . To calculate this distribution, irradiation of the films is simulated by the Geant4 toolkit. A sample of EBT3 film with 2 mm × 2 mm area is simulated. Active layer of the film is considered to contain 5000 cylindrical sensitive targets (SV) with 9.4 μ m length and 1.62 μ m diameter, located in random positions with different axial directions. The results obtained show that below an absorbed dose 1 Gy the maximum difference between the measured and the calculated optical densities is about 11%, while for the doses above 1 Gy the discrepancy is at most 3%. Eventually, it can be concluded that the sensitometric curve of EBT3 GafChromic film can satisfactorily be determined by the microdosimetric one-hit detector model, especially in the dose range above 1 Gy. … (more)
- Is Part Of:
- Physica medica. Volume 69(2020)
- Journal:
- Physica medica
- Issue:
- Volume 69(2020)
- Issue Display:
- Volume 69, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 69
- Issue:
- 2020
- Issue Sort Value:
- 2020-0069-2020-0000
- Page Start:
- 170
- Page End:
- 175
- Publication Date:
- 2020-01
- Subjects:
- Microdosimetry -- Sensitometric curve -- GafChromic films -- Photon fields
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.12.020 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12565.xml