Polyvinyl alcohol cryogel based vessel mimicking material for modelling the progression of atherosclerosis. (January 2020)
- Record Type:
- Journal Article
- Title:
- Polyvinyl alcohol cryogel based vessel mimicking material for modelling the progression of atherosclerosis. (January 2020)
- Main Title:
- Polyvinyl alcohol cryogel based vessel mimicking material for modelling the progression of atherosclerosis
- Authors:
- Malone, Andrew J.
Cournane, Sean
Naydenova, Izabela G.
Fagan, Andrew J.
Browne, Jacinta E. - Abstract:
- Highlights: The mechanical properties of polyvinyl-alcohol cryogel depend on its sample volume. The dumbbell test objects of ISO37 are mechanically analogous to vessel mimics. PVA-c can be used to produce vessel mimics with high geometric reproducibility. Abstract: Purpose: The stiffness of Polyvinyl-alcohol cryogel can be adjusted through application of consecutive freeze-thaw cycles. This material has potential applications in the production of tissue mimicking phantoms in diagnostic ultrasound. The aim of this study was to use PVA-c to produce a range of geometrically and acoustically identical vessel phantoms modelling stages of atherosclerosis which could be verified through mechanical testing, thus allowing for more precision in quantitative in-vitro flow analysis of atherosclerosis. Methods: A series of anatomically realistic walled renal artery flow phantoms were constructed using PVA-c. In order to ensure precise modelling of atherosclerosis, a modified procedure of ISO27:2017 was used to compare the mechanical properties of PVA-c. Results were compared for the standard "dumbbell" test object and a modified vessel test object. The geometric accuracy and reproducibility of the vessel models were tested before and after implantation in flow phantoms. Results: No significant difference was found between the mechanical properties of the dumbbell test samples and the vessels for any number of freeze thaw cycles, with a correlation coefficient of R 2 = 0.9767 across theHighlights: The mechanical properties of polyvinyl-alcohol cryogel depend on its sample volume. The dumbbell test objects of ISO37 are mechanically analogous to vessel mimics. PVA-c can be used to produce vessel mimics with high geometric reproducibility. Abstract: Purpose: The stiffness of Polyvinyl-alcohol cryogel can be adjusted through application of consecutive freeze-thaw cycles. This material has potential applications in the production of tissue mimicking phantoms in diagnostic ultrasound. The aim of this study was to use PVA-c to produce a range of geometrically and acoustically identical vessel phantoms modelling stages of atherosclerosis which could be verified through mechanical testing, thus allowing for more precision in quantitative in-vitro flow analysis of atherosclerosis. Methods: A series of anatomically realistic walled renal artery flow phantoms were constructed using PVA-c. In order to ensure precise modelling of atherosclerosis, a modified procedure of ISO27:2017 was used to compare the mechanical properties of PVA-c. Results were compared for the standard "dumbbell" test object and a modified vessel test object. The geometric accuracy and reproducibility of the vessel models were tested before and after implantation in flow phantoms. Results: No significant difference was found between the mechanical properties of the dumbbell test samples and the vessels for any number of freeze thaw cycles, with a correlation coefficient of R 2 = 0.9767 across the dataset, indicating that a direct comparison between the mechanical properties of the dumbbell test samples and the phantom vessels was established. The geometric reproducibility showed that before and after implantation there was no significant difference between individual vessel geometries (p = 0.337 & p = 0.176 respectively). Conclusions: Polyvinyl-alcohol cryogel is a useful material for the production of arterial flow phantoms. Care should be taken when using this material to ensure its mechanical properties have been correctly characterised. The guidelines of ISO37:2017 potentially provide the best procedure to ensure this. … (more)
- Is Part Of:
- Physica medica. Volume 69(2020)
- Journal:
- Physica medica
- Issue:
- Volume 69(2020)
- Issue Display:
- Volume 69, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 69
- Issue:
- 2020
- Issue Sort Value:
- 2020-0069-2020-0000
- Page Start:
- 1
- Page End:
- 8
- Publication Date:
- 2020-01
- Subjects:
- Mechanical characterisation -- Doppler ultrasound -- Flow phantom -- Atherosclerosis
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.11.012 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12565.xml