Deep septal deployment of a thin, lumenless pacing lead: a translational cadaver simulation study. Issue 1 (13th November 2019)
- Record Type:
- Journal Article
- Title:
- Deep septal deployment of a thin, lumenless pacing lead: a translational cadaver simulation study. Issue 1 (13th November 2019)
- Main Title:
- Deep septal deployment of a thin, lumenless pacing lead: a translational cadaver simulation study
- Authors:
- Jastrzębski, Marek
Moskal, Paweł
Hołda, Mateusz K
Strona, Marcin
Bednarek, Agnieszka
Kiełbasa, Grzegorz
Czarnecka, Danuta - Abstract:
- Abstract: Aims: The recently introduced technique of direct transseptal pacing of the left bundle branch is poorly characterized with many questions with regard to the optimal implantation strategy and safety concerns largely left unanswered. We developed a cadaver model for deep septal lead deployment in order to investigate the depth of penetration in relation to lead behaviour, lead tip position, and the number of rotations. Methods and results: Five fresh human hearts and five lumenless, 4.1-Fr pacing leads were used for deep septal deployment simulations. The leads were positioned with the use of a dedicated delivery sheath and screwed into the interventricular septum at several sites progressively more distal from the atrioventricular ring with a predetermined number of lead rotations. During each lead deployment, the depth of tip penetration was measured and the lead behaviour was noted. Four distinct lead behaviours were observed: (i) helix only penetration, no matter how many rotations were performed, due to the 'endocardial entanglement effect' (43.1% cases) or (ii) 'endocardial barrier effect' (19.6% cases), (iii) shallow/moderate penetration, with ensuing 'drill effect' when more rotations were added (9.8% cases), and (iv) deep progressive penetration with each additional rotation, occurring when the 'screwdriver effect' was present (27.4% cases, including three septal perforations). These different lead behaviours seemed to be determined by the leadAbstract: Aims: The recently introduced technique of direct transseptal pacing of the left bundle branch is poorly characterized with many questions with regard to the optimal implantation strategy and safety concerns largely left unanswered. We developed a cadaver model for deep septal lead deployment in order to investigate the depth of penetration in relation to lead behaviour, lead tip position, and the number of rotations. Methods and results: Five fresh human hearts and five lumenless, 4.1-Fr pacing leads were used for deep septal deployment simulations. The leads were positioned with the use of a dedicated delivery sheath and screwed into the interventricular septum at several sites progressively more distal from the atrioventricular ring with a predetermined number of lead rotations. During each lead deployment, the depth of tip penetration was measured and the lead behaviour was noted. Four distinct lead behaviours were observed: (i) helix only penetration, no matter how many rotations were performed, due to the 'endocardial entanglement effect' (43.1% cases) or (ii) 'endocardial barrier effect' (19.6% cases), (iii) shallow/moderate penetration, with ensuing 'drill effect' when more rotations were added (9.8% cases), and (iv) deep progressive penetration with each additional rotation, occurring when the 'screwdriver effect' was present (27.4% cases, including three septal perforations). These different lead behaviours seemed to be determined by the lead position—mainly the strength of the initial endocardial layer—and the number of fully transmitted rotations. Conclusion: New insights into deep septal lead deployment technique were gained with regard to safe and successful implantation. Graphical Abstract: … (more)
- Is Part Of:
- Europace. Volume 22:Issue 1(2020)
- Journal:
- Europace
- Issue:
- Volume 22:Issue 1(2020)
- Issue Display:
- Volume 22, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2020-0022-0001-0000
- Page Start:
- 156
- Page End:
- 161
- Publication Date:
- 2019-11-13
- Subjects:
- Left bundle branch pacing -- Deep septal pacing -- His-bundle pacing -- Perforation
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euz270 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12550.xml