1H NMR determination of 1, 3-dicyclohexylurea, glutaric acid and triethylamine in medical four-arm poly(ethylene glycol)-N-hydroxysuccinimide-glutarate for better quality control. Issue 48 (29th November 2019)
- Record Type:
- Journal Article
- Title:
- 1H NMR determination of 1, 3-dicyclohexylurea, glutaric acid and triethylamine in medical four-arm poly(ethylene glycol)-N-hydroxysuccinimide-glutarate for better quality control. Issue 48 (29th November 2019)
- Main Title:
- 1H NMR determination of 1, 3-dicyclohexylurea, glutaric acid and triethylamine in medical four-arm poly(ethylene glycol)-N-hydroxysuccinimide-glutarate for better quality control
- Authors:
- Li, Fei-Fei
Liu, Hui-Xiang
Zhang, Yan-Li
Wang, Shu-Qi - Abstract:
- Abstract : Simultaneous determination of 1, 3-dicyclohexylurea, glutaric acid and triethylamine by 1 H NMR spectroscopy for established quality control standards for residues in polymer materials. Abstract : Absorbable vascular sealing medical glue, which belongs to Class III medical devices, is a special new material for preventing the leakage of cerebrospinal fluid. Medical four-arm poly(ethylene glycol)- N -hydroxysuccinimide-glutarate (4-arm-PEG-SG) with a molecular weight of 20 000 is the main component of the absorbable medical glue. According to its quality standard, the quality control of residues 1, 3-dicyclohexylurea (DCU), glutaric acid (GA) and triethylamine (TEA) is required. A rapid analytical method of quantitative 1 H nuclear magnetic resonance ( 1 H NMR) for the determination of residues DCU, GA and TEA in medical 4-arm-PEG-SG was established in the present study. The peaks at δ 1.56 (4H, m), δ 2.71 (4H, t, J = 6.7 Hz), and δ 2.42 (6H, q, J = 7.2 Hz) were selected for quantifying DCU, GA and TEA, respectively, with deuterated pyridine as the solvent and tetramethylsilane as the internal standard. The 1 H NMR assay was validated by several experimental parameters including specificity, linearity, accuracy, precision, robustness, limit of detection (LOD), limit of quantification (LOQ) and stability. The average recoveries obtained were in the range of 99.48–102.02% for all three residues. Compared with the HPLC and GC approaches, the proposed 1 H NMR methodAbstract : Simultaneous determination of 1, 3-dicyclohexylurea, glutaric acid and triethylamine by 1 H NMR spectroscopy for established quality control standards for residues in polymer materials. Abstract : Absorbable vascular sealing medical glue, which belongs to Class III medical devices, is a special new material for preventing the leakage of cerebrospinal fluid. Medical four-arm poly(ethylene glycol)- N -hydroxysuccinimide-glutarate (4-arm-PEG-SG) with a molecular weight of 20 000 is the main component of the absorbable medical glue. According to its quality standard, the quality control of residues 1, 3-dicyclohexylurea (DCU), glutaric acid (GA) and triethylamine (TEA) is required. A rapid analytical method of quantitative 1 H nuclear magnetic resonance ( 1 H NMR) for the determination of residues DCU, GA and TEA in medical 4-arm-PEG-SG was established in the present study. The peaks at δ 1.56 (4H, m), δ 2.71 (4H, t, J = 6.7 Hz), and δ 2.42 (6H, q, J = 7.2 Hz) were selected for quantifying DCU, GA and TEA, respectively, with deuterated pyridine as the solvent and tetramethylsilane as the internal standard. The 1 H NMR assay was validated by several experimental parameters including specificity, linearity, accuracy, precision, robustness, limit of detection (LOD), limit of quantification (LOQ) and stability. The average recoveries obtained were in the range of 99.48–102.02% for all three residues. Compared with the HPLC and GC approaches, the proposed 1 H NMR method proved to be a powerful tool for quantification due to its unique advantages of simplicity, rapidity and high robustness, especially not requiring standard compounds for calibration curve preparation. … (more)
- Is Part Of:
- Analytical methods. Volume 11:Issue 48(2019)
- Journal:
- Analytical methods
- Issue:
- Volume 11:Issue 48(2019)
- Issue Display:
- Volume 11, Issue 48 (2019)
- Year:
- 2019
- Volume:
- 11
- Issue:
- 48
- Issue Sort Value:
- 2019-0011-0048-0000
- Page Start:
- 6176
- Page End:
- 6183
- Publication Date:
- 2019-11-29
- Subjects:
- Chemistry, Analytic -- Periodicals
Analytical biochemistry -- Periodicals
Chemical laboratories -- Standards -- Periodicals
543.1905 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/AY ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c9ay01471c ↗
- Languages:
- English
- ISSNs:
- 1759-9660
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0897.103700
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12546.xml