Non-paroxysmal atrial fibrillation mapping: characterization of the electrophysiological substrate using a novel integrated mapping technique. Issue 8 (5th May 2019)
- Record Type:
- Journal Article
- Title:
- Non-paroxysmal atrial fibrillation mapping: characterization of the electrophysiological substrate using a novel integrated mapping technique. Issue 8 (5th May 2019)
- Main Title:
- Non-paroxysmal atrial fibrillation mapping: characterization of the electrophysiological substrate using a novel integrated mapping technique
- Authors:
- Ciconte, Giuseppe
Vicedomini, Gabriele
Li, Wenwen
Mangual, Jan O
McSpadden, Luke
Ryu, Kyungmoo
Saviano, Massimo
Vitale, Raffaele
Conti, Manuel
Ćalović, Žarko
Santinelli, Vincenzo
Pappone, Carlo - Abstract:
- Abstract: Aims: Clinical outcomes after radiofrequency catheter ablation (RFCA) remain suboptimal in the treatment of non-paroxysmal atrial fibrillation (AF). Electrophysiological mapping may improve understanding of the underlying mechanisms. To describe the arrhythmia substrate in patients with persistent (Pers) and long-standing persistent (LSPers) AF, undergoing RFCA, using an integrated mechanism mapping technique. Methods and results: Patients underwent high-density electroanatomical mapping before and after catheter ablation. Integrated maps characterized electrogram (EGM) cycle length (CL) in regions with repetitive–regular (RR) activations, stable wavefront propagation, fragmentation, and peak-to-peak bipolar voltage. Among 83 patients (72% male, 60 ± 11 years old), RR activations were identified in 376 regions (mean CL 180 ± 31 ms). PersAF patients ( n = 43) showed more RR sites per patient (5.3 ± 2.4 vs. 3.7 ± 2.1, P = 0.002) with faster CL (166 ± 29 vs. 190 ± 29 ms; P < 0.001) and smaller surface area of fragmented EGMs (15 ± 14% vs. 27 ± 17%, P < 0.001) compared with LSPersAF. The post-ablation map in 50 patients remaining in AF, documented reduction of the RR activities per patient (1.5 ± 0.7 vs. 3.7 ± 1.4, P < 0.001) and area of fragmentation (22 ± 17% vs. 8 ± 9%, P < 0.001). Atrial fibrillation termination during ablation occurred at RR sites (0.48 ± 0.24 mV; 170.5 ± 20.2 ms CL) in 31/33 patients (94%). At the latest follow-up, arrhythmia freedom wasAbstract: Aims: Clinical outcomes after radiofrequency catheter ablation (RFCA) remain suboptimal in the treatment of non-paroxysmal atrial fibrillation (AF). Electrophysiological mapping may improve understanding of the underlying mechanisms. To describe the arrhythmia substrate in patients with persistent (Pers) and long-standing persistent (LSPers) AF, undergoing RFCA, using an integrated mechanism mapping technique. Methods and results: Patients underwent high-density electroanatomical mapping before and after catheter ablation. Integrated maps characterized electrogram (EGM) cycle length (CL) in regions with repetitive–regular (RR) activations, stable wavefront propagation, fragmentation, and peak-to-peak bipolar voltage. Among 83 patients (72% male, 60 ± 11 years old), RR activations were identified in 376 regions (mean CL 180 ± 31 ms). PersAF patients ( n = 43) showed more RR sites per patient (5.3 ± 2.4 vs. 3.7 ± 2.1, P = 0.002) with faster CL (166 ± 29 vs. 190 ± 29 ms; P < 0.001) and smaller surface area of fragmented EGMs (15 ± 14% vs. 27 ± 17%, P < 0.001) compared with LSPersAF. The post-ablation map in 50 patients remaining in AF, documented reduction of the RR activities per patient (1.5 ± 0.7 vs. 3.7 ± 1.4, P < 0.001) and area of fragmentation (22 ± 17% vs. 8 ± 9%, P < 0.001). Atrial fibrillation termination during ablation occurred at RR sites (0.48 ± 0.24 mV; 170.5 ± 20.2 ms CL) in 31/33 patients (94%). At the latest follow-up, arrhythmia freedom was higher among patients receiving ablation >75% of RR sites (Q4 82.6%, Q3 63.1%, Q2 35.1%, and Q1 0%; P < 0.001). Conclusion: The integrated mapping technique allowed characterization of multiple arrhythmic substrates in non-paroxysmal AF patients. This technique might serve as tool for a substrate-targeted ablation approach. … (more)
- Is Part Of:
- Europace. Volume 21:Issue 8(2019)
- Journal:
- Europace
- Issue:
- Volume 21:Issue 8(2019)
- Issue Display:
- Volume 21, Issue 8 (2019)
- Year:
- 2019
- Volume:
- 21
- Issue:
- 8
- Issue Sort Value:
- 2019-0021-0008-0000
- Page Start:
- 1193
- Page End:
- 1202
- Publication Date:
- 2019-05-05
- Subjects:
- Atrial fibrillation -- Persistent atrial fibrillation -- Ablation -- High-density electroanatomical mapping -- Electrophysiological substrate
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euz123 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12537.xml