Joint compensation of motion and partial volume effects by iterative deconvolution incorporating wavelet-based denoising in oncologic PET/CT imaging. (December 2019)
- Record Type:
- Journal Article
- Title:
- Joint compensation of motion and partial volume effects by iterative deconvolution incorporating wavelet-based denoising in oncologic PET/CT imaging. (December 2019)
- Main Title:
- Joint compensation of motion and partial volume effects by iterative deconvolution incorporating wavelet-based denoising in oncologic PET/CT imaging
- Authors:
- Rezaei, Sahar
Ghafarian, Pardis
Jha, Abhinav K.
Rahmim, Arman
Sarkar, Saeed
Ay, Mohammad Reza - Abstract:
- Highlights: The developed method to jointly compensate yielded improved PET quantification. Incorporation of wavelet-based denoising improved coefficient of variance. Higher contrast recovery and contrast-to-noise ratio were seen in compensated images. Abstract: Objectives: We aim to develop and rigorously evaluate an image-based deconvolution method to jointly compensate respiratory motion and partial volume effects (PVEs) for quantitative oncologic PET imaging, including studying the impact of various reconstruction algorithms on quantification performance. Procedures: An image-based deconvolution method that incorporated wavelet-based denoising within the Lucy-Richardson algorithm was implemented and assessed. The method was evaluated using phantom studies with signal-to-background ratios (SBR) of 4 and 8, and clinical data of 10 patients with 42 lung lesions ≤30 mm in diameter. In each study, PET images were reconstructed using four different algorithms: OSEM-basic, PSF, TOF, and TOFPSF. The performance was quantified using contrast recovery (CR), coefficient of variation (COV) and contrast-to-noise-ratio (CNR) metrics. Further, in each study, variabilities arising due to the four different reconstruction algorithms were assessed. Results: In phantom studies, incorporation of wavelet-based denoising improved COV in all cases. Processing images using proposed method yielded significantly higher CR and CNR particularly in small spheres, for all reconstruction algorithmsHighlights: The developed method to jointly compensate yielded improved PET quantification. Incorporation of wavelet-based denoising improved coefficient of variance. Higher contrast recovery and contrast-to-noise ratio were seen in compensated images. Abstract: Objectives: We aim to develop and rigorously evaluate an image-based deconvolution method to jointly compensate respiratory motion and partial volume effects (PVEs) for quantitative oncologic PET imaging, including studying the impact of various reconstruction algorithms on quantification performance. Procedures: An image-based deconvolution method that incorporated wavelet-based denoising within the Lucy-Richardson algorithm was implemented and assessed. The method was evaluated using phantom studies with signal-to-background ratios (SBR) of 4 and 8, and clinical data of 10 patients with 42 lung lesions ≤30 mm in diameter. In each study, PET images were reconstructed using four different algorithms: OSEM-basic, PSF, TOF, and TOFPSF. The performance was quantified using contrast recovery (CR), coefficient of variation (COV) and contrast-to-noise-ratio (CNR) metrics. Further, in each study, variabilities arising due to the four different reconstruction algorithms were assessed. Results: In phantom studies, incorporation of wavelet-based denoising improved COV in all cases. Processing images using proposed method yielded significantly higher CR and CNR particularly in small spheres, for all reconstruction algorithms and all SBRs ( P < 0.05). In patient studies, processing images using the proposed method yielded significantly higher CR and CNR ( P < 0.05). The choice of the reconstruction algorithm impacted quantification performance for changes in motion amplitude, tumor size and SBRs. Conclusions: Our results provide strong evidence that the proposed joint-compensation method can yield improved PET quantification. The choice of the reconstruction algorithm led to changes in quantitative accuracy, emphasizing the need to carefully select the right combination of reconstruction-image-based compensation methods. … (more)
- Is Part Of:
- Physica medica. Volume 68(2019)
- Journal:
- Physica medica
- Issue:
- Volume 68(2019)
- Issue Display:
- Volume 68, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 68
- Issue:
- 2019
- Issue Sort Value:
- 2019-0068-2019-0000
- Page Start:
- 52
- Page End:
- 60
- Publication Date:
- 2019-12
- Subjects:
- 18F-FDG PET/CT -- Reconstruction algorithm -- PSF -- TOF -- Combined compensation -- Respiratory motion -- Partial volume effect -- Quantification -- Lung cancer
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2019.10.031 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12520.xml