Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography. Issue 122 (January 2020)
- Record Type:
- Journal Article
- Title:
- Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography. Issue 122 (January 2020)
- Main Title:
- Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography
- Authors:
- Arendt, Christophe T.
Czwikla, Rouben
Lenga, Lukas
Wichmann, Julian L.
Albrecht, Moritz H.
Booz, Christian
Martin, Simon S.
Leithner, Doris
Tischendorf, Patricia
Blandino, Alfredo
Vogl, Thomas J.
D'Angelo, Tommaso - Abstract:
- Highlights: Objective image quality parameters peaked at 40 keV in noise-optimised VMI+ series. Vascular contrast and lesion delineation were rated best at VMI+ reconstructions. Post-processing with VMI+ may improve DE-CCTA in comparison to VMI and F_0.6 series. Abstract: Purpose: To define optimal kiloelectron volt (keV) settings for virtual monoenergetic imaging (VMI) reconstruction at dual-energy coronary computed tomography angiography (DE-CCTA). Method: Fifty-one DE-CCTA data sets (33 men; mean age, 63.9 ± 13.2 years) were reconstructed as standard linearly-blended images (F_0.6; 60% of 90 kVp, 40% of 150 kVpSn), and with traditional (VMI) and noise-optimised (VMI+) algorithms from 40 to 100 keV in 10-keV intervals. Objective image quality was assessed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. Three observers subjectively evaluated vascular contrast, image sharpness, noise and delineation of coronary plaques. Results: Median values for objective image analysis were highest in VMI + series at 40 keV (SNR, 44.5; CNR: 33.5), significantly superior (all p < 0.001) to the best VMI series at 70 keV (SNR, 28.1; CNR, 18.4) and standard F_0.6 images (SNR, 23.2; CNR, 15.6). Overall subjective metrics achieved higher scores at 40-keV VMI+ series in comparison to 70-keV VMI series and F_0.6 images (all p < 0.001), with optimal vascular contrast (5; ICC, 0.90), good image sharpness (4; 0.88), low noise (4; 0.82), and optimal plaqueHighlights: Objective image quality parameters peaked at 40 keV in noise-optimised VMI+ series. Vascular contrast and lesion delineation were rated best at VMI+ reconstructions. Post-processing with VMI+ may improve DE-CCTA in comparison to VMI and F_0.6 series. Abstract: Purpose: To define optimal kiloelectron volt (keV) settings for virtual monoenergetic imaging (VMI) reconstruction at dual-energy coronary computed tomography angiography (DE-CCTA). Method: Fifty-one DE-CCTA data sets (33 men; mean age, 63.9 ± 13.2 years) were reconstructed as standard linearly-blended images (F_0.6; 60% of 90 kVp, 40% of 150 kVpSn), and with traditional (VMI) and noise-optimised (VMI+) algorithms from 40 to 100 keV in 10-keV intervals. Objective image quality was assessed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. Three observers subjectively evaluated vascular contrast, image sharpness, noise and delineation of coronary plaques. Results: Median values for objective image analysis were highest in VMI + series at 40 keV (SNR, 44.5; CNR: 33.5), significantly superior (all p < 0.001) to the best VMI series at 70 keV (SNR, 28.1; CNR, 18.4) and standard F_0.6 images (SNR, 23.2; CNR, 15.6). Overall subjective metrics achieved higher scores at 40-keV VMI+ series in comparison to 70-keV VMI series and F_0.6 images (all p < 0.001), with optimal vascular contrast (5; ICC, 0.90), good image sharpness (4; 0.88), low noise (4; 0.82), and optimal plaque delineation (5; 0.89). Conclusions: DE-CCTA image reconstruction with 40-keV VMI + allows for significant improvement of both objective and subjective image quality. … (more)
- Is Part Of:
- European journal of radiology. Issue 122(2020)
- Journal:
- European journal of radiology
- Issue:
- Issue 122(2020)
- Issue Display:
- Volume 122, Issue 122 (2020)
- Year:
- 2020
- Volume:
- 122
- Issue:
- 122
- Issue Sort Value:
- 2020-0122-0122-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- CA contrast agent -- CCTA coronary computed tomography angiography -- CNR contrast-to-noise ratio -- DE-CCTA dual-energy coronary computed tomography angiography -- DECT dual-energy computed tomography -- keV kiloelectron volt -- PACS picture archiving and communication system -- SNR signal-to-noise ratio -- VMI virtual monoenergetic imaging -- VMI+ noise-optimised virtual monoenergetic imaging
Image enhancement -- Computed tomography angiography -- Coronary artery disease
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2019.108666 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 12515.xml