Accuracy of contrast-enhanced CT and predictive factors for extracapsular spread in unknown primary head and neck squamous cell cancer. Issue 1 (January 2020)
- Record Type:
- Journal Article
- Title:
- Accuracy of contrast-enhanced CT and predictive factors for extracapsular spread in unknown primary head and neck squamous cell cancer. Issue 1 (January 2020)
- Main Title:
- Accuracy of contrast-enhanced CT and predictive factors for extracapsular spread in unknown primary head and neck squamous cell cancer
- Authors:
- Douglas, C.
Crosbie, R.
Young, D.
Montgomery, J.
O'Neill, G.
McArthur, C. - Abstract:
- Abstract : AIM: To determine the accuracy of contrast-enhanced computed tomography (CECT) for nodal extracapsular spread (ECS) and identify predictive radiological signs and clinicopathological features for ECS in unknown-primary head and neck squamous cell cancer (UPHNSCC). MATERIALS AND METHODS: The CECT imaging of patients who underwent primary neck dissection for UPHNSCC during 2011–2015 was analysed. The largest pathological-looking node at each radiologically involved level was evaluated in consensus by two head and neck radiologists. Parameters included longest diameter, margin sharpness, haziness in adjacent fat, necrosis, and loss of fat plane with adjacent structures. Independent assessment was also made regarding the presence/absence of ECS. Findings and clinicopathological parameters were correlated with histopathology. RESULTS: Thirty-one patients with 39 neck levels had metastatic nodal involvement determined on CECT. Confirmed ECS was found at 26 levels in 23 patients. Sensitivity of radiological assessment for ECS by nodal level was 81–85% (95% confidence interval [CI]=65–93%) and specificity 46–54% (95% CI=19−81%); kappa 0.87. On univariate analysis based on the largest involved node per patient, longest diameter being ≥30 mm (p=0.007), haziness in adjacent fat (p=0.023), increasing age (p=0.006), and more advanced pathological nodal status (p=0.027) were statistically significantly associated with ECS. Haziness and increasing age were independent predictorsAbstract : AIM: To determine the accuracy of contrast-enhanced computed tomography (CECT) for nodal extracapsular spread (ECS) and identify predictive radiological signs and clinicopathological features for ECS in unknown-primary head and neck squamous cell cancer (UPHNSCC). MATERIALS AND METHODS: The CECT imaging of patients who underwent primary neck dissection for UPHNSCC during 2011–2015 was analysed. The largest pathological-looking node at each radiologically involved level was evaluated in consensus by two head and neck radiologists. Parameters included longest diameter, margin sharpness, haziness in adjacent fat, necrosis, and loss of fat plane with adjacent structures. Independent assessment was also made regarding the presence/absence of ECS. Findings and clinicopathological parameters were correlated with histopathology. RESULTS: Thirty-one patients with 39 neck levels had metastatic nodal involvement determined on CECT. Confirmed ECS was found at 26 levels in 23 patients. Sensitivity of radiological assessment for ECS by nodal level was 81–85% (95% confidence interval [CI]=65–93%) and specificity 46–54% (95% CI=19−81%); kappa 0.87. On univariate analysis based on the largest involved node per patient, longest diameter being ≥30 mm (p=0.007), haziness in adjacent fat (p=0.023), increasing age (p=0.006), and more advanced pathological nodal status (p=0.027) were statistically significantly associated with ECS. Haziness and increasing age were independent predictors on multivariate analysis (odds ratio [OR]=26.4 and 1.24). CONCLUSION: Expert assessment of ECS on CECT had good sensitivity with excellent interobserver agreement. A longest nodal diameter of ≥30 mm, haziness in the surrounding fat on CECT, advanced pathological nodal status, and advancing patient age were significantly associated with ECS in UPHNSCC patients, findings not previously reported. Highlights: CT has excellent sensitivity for extracapsular nodal spread in UPHNSCC. Nodal diameter ≥ 30 mm is statistically significantly associated with ECS in UPHNSCC. Haziness in the adjacent fat and increasing age are independent predictors of ECS in UPHNSCC on MVA. … (more)
- Is Part Of:
- Clinical radiology. Volume 75:Issue 1(2020)
- Journal:
- Clinical radiology
- Issue:
- Volume 75:Issue 1(2020)
- Issue Display:
- Volume 75, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 75
- Issue:
- 1
- Issue Sort Value:
- 2020-0075-0001-0000
- Page Start:
- 77.e23
- Page End:
- 77.e28
- Publication Date:
- 2020-01
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2019.09.138 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 12512.xml